Energidea
E3/DC S10 X 20.6

E3/DC

S10 X 20.6

Residential AIO

All-in-one residential storage system for installation and compliance comparison.

AC Phase

3P

AC Rated Power

12 kW

MPPT Count

2

Battery Capacity Min

8.25 kWh

Backup / EPS Supported

true

IP Rating

IP20

  • Complete All-In-One system made in Germany with 10-year system warranty.
  • Integrated three-phase backup power supply for the entire home including solar recharge.
  • Highly flexible installation with spatially separable battery cabinet option.
ResidentialInstaller comparisonEU market

Países aplicables

DE - GermanyAT - AustriaCH - SwitzerlandIT - ItalyNL - Netherlands

Notas por país: Primary DACH region focus.

Prompt AI para instaladores

Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.

Core Electrical

Fuente de datos

AC Phase

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

AC Rated Power

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max AC Output Current

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Power Factor Range

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

THD

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

MPPT Count

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max DC Voltage

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

MPPT Voltage Range

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Current per MPPT

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Recommended PV Power

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Efficiency

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

EU Efficiency

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

AC Phase3P
AC Rated Power12 kW
Max AC Output Current20 A
Power Factor Range0.9 leading to 0.9 lagging
THD3 %
MPPT Count2
Max DC Voltage1000 V
MPPT Voltage Range250-850 V
Max Current per MPPT27 A
Recommended PV Power18 kWp
Max Efficiency98 %
EU Efficiency95 %

Battery

Fuente de datos

Battery Chemistry

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Battery Voltage Class

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Battery Capacity Min

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Battery Capacity Max

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Charge Power

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Discharge Power

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Round-trip Efficiency

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Battery Chemistry-
Battery Voltage ClassHV
Battery Capacity Min8.25 kWh
Battery Capacity Max20.6 kWh
Max Charge Power11 kW
Max Discharge Power11 kW
Round-trip Efficiency90 %

Backup

Fuente de datos

Backup / EPS Supported

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Backup Rated Power

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Switch Time

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Black Start

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Parallel Support

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Parallel Units

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Generator Input Supported

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Backup / EPS Supportedtrue
Backup Rated Power12 kW
Switch Time20 ms
Black StartYes
Parallel SupportYes
Max Parallel Units2 units
Generator Input Supportedfalse

EMS & Communication

Fuente de datos

EMS Modes

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Export Limitation Supported

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Meter Type Supported

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Remote Monitoring Platform

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

API Supported

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

EMS ModesSelf-consumption, Backup, Time-of-Use, Vehicle2Home prepared
Export Limitation Supportedtrue
Meter Type SupportedIntegrated
Remote Monitoring PlatformE3/DC Portal
API Supportedtrue

Environment & Mechanical

Fuente de datos

Cooling Method

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

IP Rating

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Operating Temp Range

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Max Altitude

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Humidity Range

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Wiring Terminal Type

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Dimensions (W x H x D)

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Weight

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Noise

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Cooling Method-
IP RatingIP20
Operating Temp Range5 to 35
Max Altitude2000 m
Humidity Range85
Wiring Terminal TypeMC4
Max Cable Size-
Dimensions (W x H x D)1135 x 1410 x 440 mm
Weight155 kg
Noise-

Compliance & Warranty

Fuente de datos

DC Surge Protection

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

AC Surge Protection

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

AFCI

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Anti-islanding

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

Certifications

URL de origen: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Versión de origen: 2025.02

Página de origen: 2

DC Surge ProtectionType 2
AC Surge ProtectionType 2
AFCIYes
Anti-islandingYes
CertificationsVDE-AR-N 4105, CE, UN38.3

Configuracion tipica del sistema

Standard Self-Consumption

Maximizing PV self-use for high-demand German households.

Tipo de red: Three-phase

Adecuado para: New residential builds.

Componentes principales

S10 X, PV Array, Integrated Smart Meter.

Notas

Efficient DC coupling for minimal conversion losses.

Descargo de responsabilidad: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Full House Backup

Ensuring power supply during grid outages for all household loads.

Tipo de red: Three-phase

Adecuado para: Regions with frequent grid instability.

Componentes principales

S10 X, Critical Load Sub-panel.

Notas

Features automatic switchover and island mode capability.

Descargo de responsabilidad: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Archivos

Tipo: DATASHEET_PDF

S10 X 20.6 Datasheet

Abrir archivo

Tipo: BROCHURE

S10 X 20.6 Brochure

Abrir archivo

Tipo: PRODUCT_IMAGE

S10 X 20.6 Product Image

Abrir archivo

Productos relacionados