E3/DC S10 X 17.4

E3/DC

S10 X 17.4

Residential AIO

All-in-one residential storage system for installation and compliance comparison.

AC Phase

3P

AC Rated Power

12 kW

MPPT Count

2

Battery Capacity Min

8.25 kWh

Backup / EPS Supported

true

IP Rating

IP20

  • Complete All-In-One system made in Germany with 10-year system warranty.
  • Integrated three-phase backup power supply for the entire home including solar recharge.
  • Highly flexible installation with spatially separable battery cabinet option.
ResidentialInstaller comparisonEU market

Pays applicables

DE - GermanyAT - AustriaCH - SwitzerlandIT - ItalyNL - Netherlands

Notes par pays: Primary DACH region focus.

Prompt AI installateur

Générez des modèles de prompt prêts pour installateurs sur ChatGPT ou Gemini.

Core Electrical

Source de données

AC Phase

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

AC Rated Power

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max AC Output Current

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Power Factor Range

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

MPPT Count

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max DC Voltage

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

MPPT Voltage Range

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Current per MPPT

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Recommended PV Power

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Efficiency

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

EU Efficiency

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

AC Phase3P
AC Rated Power12 kW
Max AC Output Current20 A
Power Factor Range0.9 leading to 0.9 lagging
THD3 %
MPPT Count2
Max DC Voltage1000 V
MPPT Voltage Range250-850 V
Max Current per MPPT27 A
Recommended PV Power18 kWp
Max Efficiency98 %
EU Efficiency95 %

Battery

Source de données

Battery Chemistry

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Battery Voltage Class

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Battery Capacity Min

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Battery Capacity Max

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Charge Power

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Discharge Power

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Round-trip Efficiency

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Battery Chemistry-
Battery Voltage ClassHV
Battery Capacity Min8.25 kWh
Battery Capacity Max20.6 kWh
Max Charge Power9 kW
Max Discharge Power9 kW
Round-trip Efficiency90 %

Backup

Source de données

Backup / EPS Supported

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Backup Rated Power

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Switch Time

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Black Start

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Parallel Support

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Parallel Units

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Generator Input Supported

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Backup / EPS Supportedtrue
Backup Rated Power12 kW
Switch Time20 ms
Black StartYes
Parallel SupportYes
Max Parallel Units2 units
Generator Input Supportedfalse

EMS & Communication

Source de données

EMS Modes

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Export Limitation Supported

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Meter Type Supported

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Remote Monitoring Platform

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

API Supported

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

EMS ModesSelf-consumption, Backup, Time-of-Use, Vehicle2Home prepared
Export Limitation Supportedtrue
Meter Type SupportedIntegrated
Remote Monitoring PlatformE3/DC Portal
API Supportedtrue

Environment & Mechanical

Source de données

Cooling Method

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

IP Rating

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Operating Temp Range

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Max Altitude

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Humidity Range

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Wiring Terminal Type

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Dimensions (W x H x D)

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Weight

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Noise

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Cooling Method-
IP RatingIP20
Operating Temp Range5 to 35
Max Altitude2000 m
Humidity Range85
Wiring Terminal TypeMC4
Max Cable Size-
Dimensions (W x H x D)1135 x 1410 x 440 mm
Weight155 kg
Noise-

Compliance & Warranty

Source de données

DC Surge Protection

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

AC Surge Protection

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

AFCI

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Anti-islanding

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

Certifications

URL source: https://www.e3dc.com/en/wp-content/uploads/sites/3/2023/04/E3DC_TD_X-series.pdf

Version source: 2025.02

Page source: 2

DC Surge ProtectionType 2
AC Surge ProtectionType 2
AFCIYes
Anti-islandingYes
CertificationsVDE-AR-N 4105, CE, UN38.3

Configuration systeme type

Standard Self-Consumption

Maximizing PV self-use for high-demand German households.

Type de reseau: Three-phase

Adapte a: New residential builds.

Composants principaux

S10 X, PV Array, Integrated Smart Meter.

Notes

Efficient DC coupling for minimal conversion losses.

Avertissement: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Full House Backup

Ensuring power supply during grid outages for all household loads.

Type de reseau: Three-phase

Adapte a: Regions with frequent grid instability.

Composants principaux

S10 X, Critical Load Sub-panel.

Notes

Features automatic switchover and island mode capability.

Avertissement: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Fichiers

Type: DATASHEET_PDF

S10 X 17.4 Datasheet

Ouvrir le fichier

Type: BROCHURE

S10 X 17.4 Brochure

Ouvrir le fichier

Type: PRODUCT_IMAGE

S10 X 17.4 Product Image

Ouvrir le fichier

Produits liés