Energidea
SolaX SolaX X3-HYB-8.0-P

SolaX

SolaX X3-HYB-8.0-P

Residential Hybrid Inverter

Residential hybrid inverter with battery and backup interface.

AC Phase

3P

AC Rated Power

8 kW

MPPT Count

3

Battery Voltage Class

HV

Backup / EPS Supported

true

IP Rating

IP66

  • 200% PV oversizing and 110% AC output for maximum generation.
  • UPS-level switchover time <10ms for reliable backup protection.
  • High 20A MPPT current input compatible with modern high-power modules.
ResidentialInstaller comparisonEU market

Paesi applicabili

Non specificato. Contatta il vendor per l'applicabilità di mercato.

Prompt AI per installatori

Genera template di prompt pronti per installatori su ChatGPT o Gemini.

Core Electrical

Fonte dati

AC Rated Power

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max AC Output Current

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Power Factor Range

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max DC Voltage

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

MPPT Voltage Range

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max Current per MPPT

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max Efficiency

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

EU Efficiency

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

AC Phase3P
AC Rated Power8 kW
Max AC Output Current13.4 A
Power Factor Range0.8 leading ~ 0.8 lagging
THD3 %
MPPT Count3
Max DC Voltage1000 V
MPPT Voltage Range110 ~ 950 V
Max Current per MPPT20 A
Max Efficiency98 %
EU Efficiency97.7 %

Battery

Fonte dati

Battery Voltage Class

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Battery DC Voltage Range

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max Charge Power

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max Discharge Power

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Battery Voltage ClassHV
Battery DC Voltage Range130 ~ 800 V
Max Charge Power8 kW
Max Discharge Power8 kW

Backup

Fonte dati

Backup / EPS Supported

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Backup Rated Power

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Parallel Support

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Max Parallel Units

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Generator Input Supported

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Backup / EPS Supportedtrue
Backup Rated Power8 kW
Switch Time10 ms
Black StartYes
Parallel SupportYes
Max Parallel Units10 units
Generator Input Supportedtrue

EMS & Communication

Fonte dati

Export Limitation Supported

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Meter Type Supported

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Remote Monitoring Platform

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

EMS ModesSelf-use, Feed-in priority, Backup, Manual, ToU
Export Limitation Supportedtrue
Meter Type SupportedExternal Meter / CT
Remote Monitoring PlatformSolaX Cloud

Environment & Mechanical

Fonte dati

Cooling Method

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Operating Temp Range

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Dimensions (W x H x D)

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Cooling MethodFan
Max Altitude3000 m
IP RatingIP66
Operating Temp Range-35 ~ 60
Dimensions (W x H x D)560 x 503 x 210 mm
Weight38 kg
InterfacesCOM1 (BMS/RS485/Meter), COM2 (DI/DO/EVC/V2X/Heatpump)

Compliance & Warranty

Fonte dati

DC Surge Protection

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

AC Surge Protection

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Anti-islanding

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

Certifications

URL sorgente: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versione sorgente: 2.4.1

DC Surge ProtectionType II
AC Surge ProtectionType II
AFCIYes
Anti-islandingYes
CertificationsVDE-AR-N 4105, EN 50549, CEI 0-21, AS/NZS 4777

Configurazione tipica del sistema

Standard Residential Hybrid

Maximizing self-consumption with battery storage

Tipo di rete: 3P

Adatto per: Houses with 3-phase grid

Componenti principali

Hybrid Inverter, HV Battery (e.g. T-BAT), Meter

Disclaimer: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Backup System

Ensuring power supply during grid outages

Tipo di rete: 3P

Adatto per: Regions with unstable grid

Componenti principali

Hybrid Inverter, Battery, Critical Load Circuit

Disclaimer: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Smart Home / V2X

Integrating EV charging and smart load management

Tipo di rete: 3P

Adatto per: Modern energy-efficient homes

Componenti principali

Inverter, EV Charger, Heat Pump

Disclaimer: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

File

Tipo: DATASHEET_PDF

SolaX X3-HYB-8.0-P Datasheet

Apri file

Tipo: INSTALLATION_MANUAL

SolaX X3-HYB-8.0-P Installation Manual

Apri file

Tipo: PRODUCT_IMAGE

SolaX X3-HYB-8.0-P Product Image

Apri file