SolaX SolaX X3-HYB-8.0-P

SolaX

SolaX X3-HYB-8.0-P

Residential Hybrid Inverter

Residential hybrid inverter with battery and backup interface.

AC Phase

3P

AC Rated Power

8 kW

MPPT Count

3

Battery Voltage Class

HV

Backup / EPS Supported

true

IP Rating

IP66

  • 200% PV oversizing and 110% AC output for maximum generation.
  • UPS-level switchover time <10ms for reliable backup protection.
  • High 20A MPPT current input compatible with modern high-power modules.
ResidentialInstaller comparisonEU market

Țări aplicabile

Nespecificat. Contactează vendorul pentru aplicabilitate de piață.

Prompt AI pentru instalatori

Generează șabloane de prompt pregătite pentru instalatori în ChatGPT sau Gemini.

AC Phase3P
AC Rated Power8 kW
Max AC Output Current13.4 A
Power Factor Range0.8 leading ~ 0.8 lagging
THD3 %
MPPT Count3
Max DC Voltage1000 V
MPPT Voltage Range110 ~ 950 V
Max Current per MPPT20 A
Max Efficiency98 %
EU Efficiency97.7 %

Battery

Sursă date

Battery Voltage Class

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Battery DC Voltage Range

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Max Discharge Power

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Battery Voltage ClassHV
Battery DC Voltage Range130 ~ 800 V
Max Charge Power8 kW
Max Discharge Power8 kW

Backup

Sursă date

Backup / EPS Supported

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Backup Rated Power

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Max Parallel Units

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Generator Input Supported

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Backup / EPS Supportedtrue
Backup Rated Power8 kW
Switch Time10 ms
Black StartYes
Parallel SupportYes
Max Parallel Units10 units
Generator Input Supportedtrue

EMS & Communication

Sursă date

Export Limitation Supported

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Meter Type Supported

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Remote Monitoring Platform

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

EMS ModesSelf-use, Feed-in priority, Backup, Manual, ToU
Export Limitation Supportedtrue
Meter Type SupportedExternal Meter / CT
Remote Monitoring PlatformSolaX Cloud

Environment & Mechanical

Sursă date

Operating Temp Range

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Dimensions (W x H x D)

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

Cooling MethodFan
Max Altitude3000 m
IP RatingIP66
Operating Temp Range-35 ~ 60
Dimensions (W x H x D)560 x 503 x 210 mm
Weight38 kg
InterfacesCOM1 (BMS/RS485/Meter), COM2 (DI/DO/EVC/V2X/Heatpump)

Compliance & Warranty

Sursă date

DC Surge Protection

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

AC Surge Protection

URL sursă: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Versiune sursă: 2.4.1

DC Surge ProtectionType II
AC Surge ProtectionType II
AFCIYes
Anti-islandingYes
CertificationsVDE-AR-N 4105, EN 50549, CEI 0-21, AS/NZS 4777

Configuratie tipica de sistem

Standard Residential Hybrid

Maximizing self-consumption with battery storage

Tip de retea: 3P

Potrivit pentru: Houses with 3-phase grid

Componente principale

Hybrid Inverter, HV Battery (e.g. T-BAT), Meter

Declinare: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Backup System

Ensuring power supply during grid outages

Tip de retea: 3P

Potrivit pentru: Regions with unstable grid

Componente principale

Hybrid Inverter, Battery, Critical Load Circuit

Declinare: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Smart Home / V2X

Integrating EV charging and smart load management

Tip de retea: 3P

Potrivit pentru: Modern energy-efficient homes

Componente principale

Inverter, EV Charger, Heat Pump

Declinare: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Fișiere

Tip: DATASHEET_PDF

SolaX X3-HYB-8.0-P Datasheet

Deschide fișierul

Tip: INSTALLATION_MANUAL

SolaX X3-HYB-8.0-P Installation Manual

Deschide fișierul

Tip: PRODUCT_IMAGE

SolaX X3-HYB-8.0-P Product Image

Deschide fișierul

Produse similare