Energidea
Dyness Dyness Tower T7

Dyness

Dyness Tower T7

Residential Battery

Residential battery module/stack for hybrid systems.

Battery Chemistry

LFP

Battery Voltage Class

HV

Capacity (Nominal)

7.1 kWh

Capacity (Usable)

6.745 kWh

Max Discharge Power

4.26 kW

IP Rating

IP54

  • Quick installation with cable-free stackable modular design.
  • High protection level IP54 suitable for outdoor residential installation.
  • High voltage efficiency and wide compatibility with leading hybrid inverters.
ResidentialInstaller comparisonEU market

Países aplicables

AT - AustriaBE - BelgiumBG - BulgariaCY - CyprusCZ - CzechiaDE - GermanyDK - DenmarkEE - EstoniaES - SpainFI - Finland
Los campos clave de comparación están incompletos (>30% faltante). Aún no se recomienda comparación directa.

Prompt AI para instaladores

Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.

Battery

Fuente de datos

Battery Chemistry

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Battery Voltage Class

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Capacity (Nominal)

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Capacity (Usable)

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Nominal Voltage

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Voltage Range

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Min Modules

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Max Modules

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Installation Type

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Capacity Scalability Min

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Capacity Scalability Max

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Max Charge Power

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Max Discharge Power

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Peak Discharge Power

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Cycle Life

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

DoD

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Round-trip Efficiency

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Battery ChemistryLFP
Battery Voltage ClassHV
Capacity (Nominal)7.1 kWh
Capacity (Usable)6.745 kWh
Nominal Voltage192 V
Voltage Range168 ~ 219 V
Min Modules2
Max Modules6
Installation Type-
Capacity Scalability Min7.1 kWh
Capacity Scalability Max255.72 kWh
Max Charge Power4.26 kW
Max Discharge Power4.26 kW
Peak Discharge Power4.26 kW
Cycle Life6000 cycles
DoD95 %
Round-trip Efficiency95 %

Environment & Mechanical

Fuente de datos

IP Rating

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Charge Temp Range

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Discharge Temp Range

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Heating Supported

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Dimensions (W x H x D)

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Weight

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

IP RatingIP54
Charge Temp Range0 ~ 50
Discharge Temp Range-10 ~ 50
Heating Supportedfalse
Dimensions (W x H x D)504*380*700 mm
Weight105 kg

EMS & Communication

Fuente de datos

BMS Interfaces

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Compatible Inverters

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

BMS Update Supported

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

BMS InterfacesCAN / RS485
Compatible InvertersKostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt, ATESS, Sineng, etc.
BMS Update Supportedtrue

Compliance & Warranty

Fuente de datos

Certifications

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

Shipping Certifications

URL de origen: https://dyness.com/Public/Uploads/uploadfile/files/20250318/DynessTowerdatasheet20240103EN.pdf

Versión de origen: 20240103EN

Página de origen: 2

CertificationsUN38.3, CE-EMC, IEC62040, IEC62619, IEC62477, IEC60730, IEC63056, UKCA, CEC Accredited, UL1973, VDE2510-50
Shipping CertificationsUN38.3

Archivos

Tipo: DATASHEET_PDF

Dyness Tower T7 Datasheet

Abrir archivo

Tipo: PRODUCT_IMAGE

Dyness Tower T7 Product Image

Abrir archivo