Energidea
SolaX SolaX X3-HYB-15.0-P

SolaX

SolaX X3-HYB-15.0-P

Residential Hybrid Inverter

Residential hybrid inverter with battery and backup interface.

AC Phase

3P

AC Rated Power

15 kW

MPPT Count

3

Battery Voltage Class

HV

Backup / EPS Supported

true

IP Rating

IP66

  • 200% PV oversizing and 110% AC output for maximum generation.
  • UPS-level switchover time <10ms for reliable backup protection.
  • High 20A MPPT current input compatible with modern high-power modules.
ResidentialInstaller comparisonEU market

Pays applicables

Non spécifié. Contactez le fournisseur pour l'applicabilité marché.

Prompt AI installateur

Générez des modèles de prompt prêts pour installateurs sur ChatGPT ou Gemini.

AC Phase3P
AC Rated Power15 kW
Max AC Output Current24.3 A
Power Factor Range0.8 leading ~ 0.8 lagging
THD3 %
MPPT Count3
Max DC Voltage1000 V
MPPT Voltage Range110 ~ 950 V
Max Current per MPPT20 A
Max Efficiency98 %
EU Efficiency97.7 %

Battery

Source de données

Battery Voltage Class

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Battery DC Voltage Range

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Max Discharge Power

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Battery Voltage ClassHV
Battery DC Voltage Range130 ~ 800 V
Max Charge Power15 kW
Max Discharge Power15 kW

Backup

Source de données

Backup / EPS Supported

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Backup Rated Power

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Max Parallel Units

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Generator Input Supported

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Backup / EPS Supportedtrue
Backup Rated Power15 kW
Switch Time10 ms
Black StartYes
Parallel SupportYes
Max Parallel Units10 units
Generator Input Supportedtrue

EMS & Communication

Source de données

Export Limitation Supported

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Meter Type Supported

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Remote Monitoring Platform

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

EMS ModesSelf-use, Feed-in priority, Backup, Manual, ToU
Export Limitation Supportedtrue
Meter Type SupportedExternal Meter / CT
Remote Monitoring PlatformSolaX Cloud

Environment & Mechanical

Source de données

Operating Temp Range

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Dimensions (W x H x D)

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

Cooling MethodFan
Max Altitude3000 m
IP RatingIP66
Operating Temp Range-35 ~ 60
Dimensions (W x H x D)560 x 503 x 210 mm
Weight38 kg
InterfacesCOM1 (BMS/RS485/Meter), COM2 (DI/DO/EVC/V2X/Heatpump)

Compliance & Warranty

Source de données

DC Surge Protection

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

AC Surge Protection

URL source: https://www.solaxpower.com/uploads/file/solax-x3-hyb-g4-pro-datasheet-en.pdf

Version source: 2.4.1

DC Surge ProtectionType II
AC Surge ProtectionType II
AFCIYes
Anti-islandingYes
CertificationsVDE-AR-N 4105, EN 50549, CEI 0-21, AS/NZS 4777

Configuration systeme type

Standard Residential Hybrid

Maximizing self-consumption with battery storage

Type de reseau: 3P

Adapte a: Houses with 3-phase grid

Composants principaux

Hybrid Inverter, HV Battery (e.g. T-BAT), Meter

Avertissement: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Backup System

Ensuring power supply during grid outages

Type de reseau: 3P

Adapte a: Regions with unstable grid

Composants principaux

Hybrid Inverter, Battery, Critical Load Circuit

Avertissement: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Smart Home / V2X

Integrating EV charging and smart load management

Type de reseau: 3P

Adapte a: Modern energy-efficient homes

Composants principaux

Inverter, EV Charger, Heat Pump

Avertissement: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Fichiers

Type: DATASHEET_PDF

SolaX X3-HYB-15.0-P Datasheet

Ouvrir le fichier

Type: INSTALLATION_MANUAL

SolaX X3-HYB-15.0-P Installation Manual

Ouvrir le fichier

Type: PRODUCT_IMAGE

SolaX X3-HYB-15.0-P Product Image

Ouvrir le fichier

Produits liés