Self-Consumption
Residential power optimizationType de reseau: On-grid
Adapte a: Homeowners
Composants principaux
PV, Battery, Inverter, Meter

GoodWe
Single-phase hybrid inverter with 0 kWh LFP battery
In the GoodWe ES G2 Series series
Ideal for installers who need a balanced this capacity class option with 3.6 kW for mainstream project sizing.
Rated Output Power
3.6 kW
Vendor| AC Phase | 1PVendor |
| AC Rated Power | 3.6 kWVendor |
| Max AC Output Current | 15.7 AVendor |
| Power Factor Range | 0.8 leading ~ 0.8 laggingVendor |
| THD | -Vendor |
| MPPT Count | 2Vendor |
| Max DC Voltage | 600 VVendor |
| MPPT Voltage Range | 60 ~ 550 VVendor |
| Max Current per MPPT | 16 AVendor |
| Max Efficiency | 97.6 %Vendor |
| EU Efficiency | 96.7 %Vendor |
| Battery Voltage Class | LVVendor |
| Battery DC Voltage Range | 40 ~ 60 VVendor |
| Max Charge Power | 3.6 kWVendor |
| Max Discharge Power | 3.6 kWVendor |
| Backup / EPS Supported | trueVendor |
| Backup Rated Power | 3.6 kWVendor |
| Switch Time | 10 msVendor |
| Black Start | YesVendor |
| Parallel Support | YesVendor |
| Max Parallel Units | 6 unitsVendor |
| Generator Input Supported | trueVendor |
| EMS Modes | Self-consumption, Backup, TOUVendor |
| Export Limitation Supported | trueVendor |
| Meter Type Supported | GM1000/GM3000Vendor |
| Remote Monitoring Platform | SEMS PortalVendor |
| Cooling Method | NaturalVendor |
| Max Altitude | 3000 mVendor |
| IP Rating | IP65Vendor |
| Operating Temp Range | -35 ~ +60Vendor |
| Dimensions (W x H x D) | 435 x 506 x 155 mmVendor |
| Weight | 20.8 kgVendor |
| Interfaces | RS485, CAN, WiFi, LANVendor |
| DC Surge Protection | Type IIIVendor |
| AC Surge Protection | Type IIIVendor |
| AFCI | -Vendor |
| Anti-islanding | -Vendor |
| Certifications | VDE-AR-N 4105, EN 50549-1, CEI 0-21, G98/G99Vendor |
Run a single-product scenario check using the same Product Match rules.
No compliance data available for this product.
-
Product data is sourced from manufacturers, official websites, and community contributions. Energidea does not guarantee completeness or accuracy. Installers should verify specifications, certifications, and compatibility with manufacturer documentation before quotation.
Générez des modèles de prompt prêts pour installateurs sur ChatGPT ou Gemini.
Type de reseau: On-grid
Adapte a: Homeowners
Composants principaux
PV, Battery, Inverter, Meter
Type de reseau: On/Off-grid
Adapte a: Critical load protection
Composants principaux
PV, Battery, Inverter