Pylontech
Pylontech Force H3X-12
Residential AIO
All-in-one residential storage system for installation and compliance comparison.
AC Phase
3P
AC Rated Power
12 kW
MPPT Count
2
Battery Capacity Min
10.24 kWh
Backup / EPS Supported
true
IP Rating
IP65
- Seamless backup transition in less than 10ms.
- Modular design for flexible capacity expansion from 10 to 61 kWh.
- High-efficiency 3-phase hybrid integration with 100% unbalanced load support.
Applicable Countries
Installer AI Prompt
Generate installer-ready prompt templates for ChatGPT or Gemini.
Core Electrical
Data source
AC Phase
Source Version: 240611(2)
AC Rated Power
Source Version: 240611(2)
Max AC Output Current
Source Version: 240611(2)
Power Factor Range
Source Version: 240611(2)
THD
Source Version: 240611(2)
MPPT Count
Source Version: 240611(2)
Max DC Voltage
Source Version: 240611(2)
MPPT Voltage Range
Source Version: 240611(2)
Max Current per MPPT
Source Version: 240611(2)
Recommended PV Power
Source Version: 240611(2)
Max Efficiency
Source Version: 240611(2)
EU Efficiency
Source Version: 240611(2)
| AC Phase | 3P |
| AC Rated Power | 12 kW |
| Max AC Output Current | 19.1 A |
| Power Factor Range | 0.8 leading - 0.8 lagging |
| THD | 3 % |
| MPPT Count | 2 |
| Max DC Voltage | 1000 V |
| MPPT Voltage Range | 180 - 950 V |
| Max Current per MPPT | - |
| Recommended PV Power | 18 kWp |
| Max Efficiency | 98.4 % |
| EU Efficiency | 97.5 % |
Battery
Data source
Battery Chemistry
Source Version: 240611(2)
Battery Voltage Class
Source Version: 240611(2)
Battery Capacity Min
Source Version: 240611(2)
Battery Capacity Max
Source Version: 240611(2)
Max Charge Power
Source Version: 240611(2)
Max Discharge Power
Source Version: 240611(2)
| Battery Chemistry | LFP |
| Battery Voltage Class | HV |
| Battery Capacity Min | 10.24 kWh |
| Battery Capacity Max | 61.44 kWh |
| Max Charge Power | 12 kW |
| Max Discharge Power | 12 kW |
| Round-trip Efficiency | - |
Backup
Data source
Backup / EPS Supported
Source Version: 240611(2)
Backup Rated Power
Source Version: 240611(2)
Switch Time
Source Version: 240611(2)
Black Start
Source Version: 240611(2)
Parallel Support
Source Version: 240611(2)
Max Parallel Units
Source Version: 240611(2)
| Backup / EPS Supported | true |
| Backup Rated Power | 12 kW |
| Switch Time | 10 ms |
| Black Start | Yes |
| Parallel Support | Yes |
| Max Parallel Units | 10 units |
| Generator Input Supported | - |
EMS & Communication
Data source
EMS Modes
Source Version: 240611(2)
Export Limitation Supported
Source Version: 240611(2)
Meter Type Supported
Source Version: 240611(2)
Remote Monitoring Platform
Source Version: 240611(2)
| EMS Modes | Self-consumption, Time-of-use |
| Export Limitation Supported | true |
| Meter Type Supported | External CT or Smart Meter |
| Remote Monitoring Platform | Pylon Cloud |
| API Supported | - |
Environment & Mechanical
Data source
Cooling Method
Source Version: 240611(2)
IP Rating
Source Version: 240611(2)
Operating Temp Range
Source Version: 240611(2)
Max Altitude
Source Version: 240611(2)
Humidity Range
Source Version: 240611(2)
Wiring Terminal Type
Source Version: 240611(2)
Dimensions (W x H x D)
Source Version: 240611(2)
Weight
Source Version: 240611(2)
Noise
Source Version: 240611(2)
| Cooling Method | Natural |
| IP Rating | IP65 |
| Operating Temp Range | -20 to 60 |
| Max Altitude | 3000 m |
| Humidity Range | 0-95% |
| Wiring Terminal Type | Plug and Play |
| Max Cable Size | - |
| Dimensions (W x H x D) | 700 x 310 x 1410 mm |
| Weight | 34.5 kg |
| Noise | 30 dB(A) |
Compliance & Warranty
Data source
DC Surge Protection
Source Version: 240611(2)
AC Surge Protection
Source Version: 240611(2)
AFCI
Source Version: 240611(2)
Anti-islanding
Source Version: 240611(2)
Certifications
Source Version: 240611(2)
| DC Surge Protection | Type II |
| AC Surge Protection | Type II |
| AFCI | Yes |
| Anti-islanding | Yes |