SolarEdge
SE4000H
Residential Hybrid Inverter
Residential hybrid inverter with battery and backup interface.
AC Phase
1P
AC Rated Power
4 kW
MPPT Count
1
Battery Voltage Class
HV
Backup / EPS Supported
true
IP Rating
IP65
Applicable Countries
Installer AI Prompt
Generate installer-ready prompt templates for ChatGPT or Gemini.
Core Electrical
Data source
AC Phase
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
AC Rated Power
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max AC Output Current
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Power Factor Range
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
THD
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
MPPT Count
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max DC Voltage
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
MPPT Voltage Range
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Current per MPPT
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Efficiency
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
EU Efficiency
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| AC Phase | 1P |
| AC Rated Power | 4 kW |
| Max AC Output Current | 18.5 A |
| Power Factor Range | 1 (adjustable -0.8 to 0.8) |
| THD | - |
| MPPT Count | 1 |
| Max DC Voltage | 480 V |
| MPPT Voltage Range | 380-480 V |
| Max Current per MPPT | 27.5 A |
| Max Efficiency | 99.2 % |
| EU Efficiency | 99 % |
Battery
Data source
Battery Voltage Class
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Battery DC Voltage Range
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Charge Power
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Discharge Power
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| Battery Voltage Class | HV |
| Battery DC Voltage Range | 370-450 V |
| Max Charge Power | 4 kW |
| Max Discharge Power | 4 kW |
Backup
Data source
Backup / EPS Supported
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Backup Rated Power
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Switch Time
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Black Start
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Parallel Support
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Parallel Units
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Generator Input Supported
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| Backup / EPS Supported | true |
| Backup Rated Power | 4 kW |
| Switch Time | 2000 ms |
| Black Start | Yes |
| Parallel Support | Yes |
| Max Parallel Units | 3 units |
| Generator Input Supported | true |
EMS & Communication
Data source
EMS Modes
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Export Limitation Supported
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Meter Type Supported
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Remote Monitoring Platform
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| EMS Modes | Self-consumption, Backup, Time-of-use |
| Export Limitation Supported | true |
| Meter Type Supported | SolarEdge Home Inline Meter |
| Remote Monitoring Platform | SolarEdge Monitoring |
Environment & Mechanical
Data source
Cooling Method
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Max Altitude
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
IP Rating
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Operating Temp Range
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Dimensions (W x H x D)
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Weight
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Interfaces
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| Cooling Method | Natural |
| Max Altitude | - |
| IP Rating | IP65 |
| Operating Temp Range | -40 to 60 |
| Dimensions (W x H x D) | 535*370*185 mm |
| Weight | 19.6 kg |
| Interfaces | - |
Compliance & Warranty
Data source
DC Surge Protection
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
AC Surge Protection
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
AFCI
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Anti-islanding
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
Certifications
Source URL: https://knowledge-center.solaredge.com/sites/kc/files/se-home-hub-single-phase-inverter-datasheet-eu.pdf
Source Version: 2024
Source Page: 2
| DC Surge Protection | - |
| AC Surge Protection | - |
| AFCI | - |
| Anti-islanding | - |
| Certifications | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 |
Grid Connection Compliance by Country
| Country | Status | Grid Code | Evidence | Notes |
|---|---|---|---|---|
| DE | Approved | VDE-AR-N 4105 | Open file | Fully compliant with German residential grid connection requirements. |