Full Home Backup
Residential split-phase backupGrid Type: Split-Phase 120/240V
Suitable For: Homeowners
Main Components
PV, LV Battery, Inverter, Smart Meter
GoodWe
Residential Hybrid Inverter
Residential hybrid inverter with battery and backup interface.
AC Phase
1P
AC Rated Power
10 kW
MPPT Count
2
Battery Voltage Class
LV
Backup / EPS Supported
true
IP Rating
IP IP66
Applicable Countries
Not specified. Please contact vendor for market applicability.
Generate installer-ready prompt templates for ChatGPT or Gemini.
AC Phase
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
AC Rated Power
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max AC Output Current
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Power Factor Range
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
MPPT Count
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max DC Voltage
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
MPPT Voltage Range
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Current per MPPT
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Efficiency
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
EU Efficiency
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| AC Phase | 1P |
| AC Rated Power | 10 kW |
| Max AC Output Current | 41.7 A |
| Power Factor Range | 0.8 leading ~ 0.8 lagging |
| THD | - |
| MPPT Count | 2 |
| Max DC Voltage | 600 V |
| MPPT Voltage Range | 50 ~ 550 V |
| Max Current per MPPT | - |
| Max Efficiency | 97.6 % |
| EU Efficiency | 97 % |
Battery Voltage Class
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Battery DC Voltage Range
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Charge Power
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Discharge Power
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| Battery Voltage Class | LV |
| Battery DC Voltage Range | 40 ~ 60 V |
| Max Charge Power | 10.6 kW |
| Max Discharge Power | 10.6 kW |
Backup / EPS Supported
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Backup Rated Power
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Switch Time
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Black Start
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Parallel Support
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Parallel Units
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Generator Input Supported
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| Backup / EPS Supported | true |
| Backup Rated Power | 10 kW |
| Switch Time | 4 ms |
| Black Start | Yes |
| Parallel Support | Yes |
| Max Parallel Units | 16 units |
| Generator Input Supported | true |
EMS Modes
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Export Limitation Supported
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Meter Type Supported
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Remote Monitoring Platform
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| EMS Modes | Self-consumption, Backup, TOU, Off-grid |
| Export Limitation Supported | true |
| Meter Type Supported | GM1000/GM3000 |
| Remote Monitoring Platform | SEMS Portal |
Cooling Method
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Max Altitude
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
IP Rating
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Operating Temp Range
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Dimensions (W x H x D)
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Interfaces
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| Cooling Method | Natural |
| Max Altitude | 3000 m |
| IP Rating | IP IP66 |
| Operating Temp Range | -35 ~ +60 |
| Dimensions (W x H x D) | 561 x 415 x 204 mm |
| Weight | 35 kg |
| Interfaces | RS485, CAN, WiFi, LAN, Bluetooth |
DC Surge Protection
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
AC Surge Protection
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Anti-islanding
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
Certifications
Source URL: https://en.goodwe.com/Skippower/downloadFileF?id=3924&mid=60
Source Version: 2024
| DC Surge Protection | Type III |
| AC Surge Protection | Type III |
| AFCI | Yes |
| Anti-islanding | Yes |
| Certifications | IEEE 1547, UL1741, Rule 21 |
Grid Type: Split-Phase 120/240V
Suitable For: Homeowners
Main Components
PV, LV Battery, Inverter, Smart Meter
Grid Type: Off-grid
Suitable For: Rural application
Main Components
PV, Battery, Inverter, Generator