Energidea
SolaX SolaX X3-IES-6K

SolaX

SolaX X3-IES-6K

Residential AIO

All-in-one residential storage system for installation and compliance comparison.

AC Phase

3P

AC Rated Power

6 kW

MPPT Count

2

Battery Capacity Min

9.2 kWh

Backup / EPS Supported

true

IP Rating

IP66

  • UPS-level <10ms switchover time for seamless critical load protection.
  • All-in-one modular stack design (5.1kWh modules) for fast 30-minute installation.
  • Robust IP66 protection and built-in Type II SPD on both AC and DC sides.
ResidentialInstaller comparisonEU market

Países aplicáveis

DE - GermanyAT - AustriaCH - SwitzerlandCZ - CzechiaPL - PolandUK - United KingdomIE - IrelandIT - ItalyES - SpainRO - Romania

Prompt AI para instaladores

Gere modelos de prompt prontos para instaladores no ChatGPT ou Gemini.

Core Electrical

Fonte de dados

AC Phase

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

AC Rated Power

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max AC Output Current

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Power Factor Range

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

MPPT Count

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max DC Voltage

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

MPPT Voltage Range

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Current per MPPT

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Recommended PV Power

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Efficiency

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

EU Efficiency

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

AC Phase3P
AC Rated Power6 kW
Max AC Output Current9.6 A
Power Factor Range0.8 leading ~ 0.8 lagging
THD-
MPPT Count2
Max DC Voltage1000 V
MPPT Voltage Range110-950 V
Max Current per MPPT-
Recommended PV Power12 kWp
Max Efficiency98.3 %
EU Efficiency97.8 %

Battery

Fonte de dados

Battery Chemistry

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Battery Voltage Class

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Battery Capacity Min

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Battery Capacity Max

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Charge Power

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Discharge Power

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Round-trip Efficiency

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Battery ChemistryLFP
Battery Voltage ClassHV
Battery Capacity Min9.2 kWh
Battery Capacity Max27.6 kWh
Max Charge Power6 kW
Max Discharge Power6 kW
Round-trip Efficiency95 %

Backup

Fonte de dados

Backup / EPS Supported

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Backup Rated Power

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Switch Time

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Black Start

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Parallel Support

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Parallel Units

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Generator Input Supported

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Backup / EPS Supportedtrue
Backup Rated Power6 kW
Switch Time10 ms
Black StartYes
Parallel SupportYes
Max Parallel Units10 units
Generator Input Supportedtrue

EMS & Communication

Fonte de dados

EMS Modes

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Export Limitation Supported

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Meter Type Supported

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Remote Monitoring Platform

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

EMS ModesSelf-use, Feed-in Priority, Backup, Manual
Export Limitation Supportedtrue
Meter Type SupportedThree-phase meter, CT
Remote Monitoring PlatformSolaXCloud
API Supported-

Environment & Mechanical

Fonte de dados

Cooling Method

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

IP Rating

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Operating Temp Range

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Max Altitude

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Humidity Range

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Wiring Terminal Type

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Dimensions (W x H x D)

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Cooling MethodNatural
IP RatingIP66
Operating Temp Range-30 to 53
Max Altitude3000 m
Humidity Range0-100% (non-condensing)
Wiring Terminal TypePlug & Play
Max Cable Size-
Dimensions (W x H x D)717 x 405 x 209.5 mm
Weight37 kg
Noise30 dB(A)

Compliance & Warranty

Fonte de dados

DC Surge Protection

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

AC Surge Protection

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Anti-islanding

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

Certifications

URL de origem: https://www.solaxpower.com/uploads/file/solax-x3-ies-datasheet-en.pdf

Versão da origem: V1.8

DC Surge ProtectionType II
AC Surge ProtectionType II
AFCI-
Anti-islandingYes
CertificationsVDE4105, EN 50549, AS 4777, G98/G99, CE, TUV

Configuracao tipica do sistema

Residential Self-consumption

Maximizing solar energy usage at home to minimize grid reliance.

Tipo de rede: Three Phase

Adequado para: Homeowners with high daytime solar generation and high evening consumption.

Componentes principais

X3-IES, PV Array, Triple Power Battery Modules, Smart Meter.

Isencao de responsabilidade: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Backup / Off-grid Mode

Providing power to critical loads during grid outages or for off-grid sites.

Tipo de rede: Three Phase / Off-grid

Adequado para: Areas with unstable grids or critical mission residential power requirements.

Componentes principais

X3-IES, Battery modules, Critical load circuit.

Isencao de responsabilidade: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Ficheiros

Tipo: DATASHEET_PDF

SolaX X3-IES-6K Datasheet

Abrir ficheiro

Tipo: INSTALLATION_MANUAL

SolaX X3-IES-6K Installation Manual

Abrir ficheiro

Tipo: CERTIFICATES

SolaX X3-IES-6K Certificates

Abrir ficheiro

Tipo: PRODUCT_IMAGE

SolaX X3-IES-6K Product Image

Abrir ficheiro

Produtos relacionados