Energidea
SolarEdge SE5000H-BUS

SolarEdge

SE5000H-BUS

Residential Hybrid Inverter

Residential hybrid inverter with battery and backup interface.

AC Phase

1P

AC Rated Power

5 kW

MPPT Count

1

Battery Voltage Class

HV

Backup / EPS Supported

true

IP Rating

IP65

  • Industry-leading 99% weighted efficiency for maximum energy yield.
  • DC-coupled architecture eliminates unnecessary power conversions.
  • Wireless battery communication simplifies installation and cabling.
ResidentialInstaller comparisonEU market

Kraje zastosowania

AT - AustriaBE - BelgiumCH - SwitzerlandDE - GermanyES - SpainFR - FranceIT - ItalyLU - LuxembourgNL - NetherlandsPL - Poland

Uwagi krajowe: Requires SolarEdge Home Network for battery communication.

Prompt AI dla instalatorów

Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.

Core Electrical

Źródło danych

AC Phase

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

AC Rated Power

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max AC Output Current

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Power Factor Range

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

MPPT Count

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max DC Voltage

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

MPPT Voltage Range

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Current per MPPT

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Efficiency

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

EU Efficiency

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

AC Phase1P
AC Rated Power5 kW
Max AC Output Current23 A
Power Factor Range0.8 leading to 0.8 lagging
THD3 %
MPPT Count1
Max DC Voltage480 V
MPPT Voltage Range380-480 V
Max Current per MPPT13.5 A
Max Efficiency99.2 %
EU Efficiency99 %

Battery

Źródło danych

Battery Voltage Class

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Battery DC Voltage Range

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Charge Power

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Discharge Power

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Battery Voltage ClassHV
Battery DC Voltage Range350-450 V
Max Charge Power5 kW
Max Discharge Power5 kW

Backup

Źródło danych

Backup / EPS Supported

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Backup Rated Power

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Switch Time

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Black Start

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Parallel Support

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Parallel Units

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Generator Input Supported

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Backup / EPS Supportedtrue
Backup Rated Power5 kW
Switch Time2000 ms
Black StartYes
Parallel SupportYes
Max Parallel Units3 units
Generator Input Supportedfalse

EMS & Communication

Źródło danych

EMS Modes

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Export Limitation Supported

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Meter Type Supported

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Remote Monitoring Platform

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

EMS ModesSelf-consumption, Backup, Time-of-Use
Export Limitation Supportedtrue
Meter Type SupportedSolarEdge Home Inline Meter
Remote Monitoring PlatformSolarEdge Monitoring Portal

Environment & Mechanical

Źródło danych

Cooling Method

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Max Altitude

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

IP Rating

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Operating Temp Range

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Dimensions (W x H x D)

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Interfaces

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Cooling Method-
Max Altitude2000 m
IP RatingIP65
Operating Temp Range-40 to 60
Dimensions (W x H x D)450 x 370 x 174 mm
Weight12 kg
InterfacesRS485, Ethernet, WLAN, Home Network

Compliance & Warranty

Źródło danych

DC Surge Protection

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

AC Surge Protection

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Anti-islanding

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

Certifications

URL źródła: https://www.solaredge.com/sites/default/files/se-single-phase-home-hub-inverter-datasheet-en.pdf

Wersja źródła: v1.4

Strona źródła: 2

DC Surge Protection-
AC Surge Protection-
AFCIYes
Anti-islandingYes
CertificationsIEC62109, VDE-AR-N 4105, G98/G99, EN 50549-1

Typowa konfiguracja systemu

Optimization of Self-Consumption

Standard home storage without backup requirements.

Typ sieci: Single-phase

Odpowiednie dla: New residential systems.

Glowne komponenty

SE Hub Inverter, Home Battery 400V, Inline Meter.

Notatki

Lowest installation cost.

Zastrzezenie: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Full Home Backup

Protection against grid outages for entire household.

Typ sieci: Single-phase

Odpowiednie dla: Regions with unreliable grid infrastructure.

Glowne komponenty

SE Hub Inverter, Home Battery 400V, Home Backup Interface.

Notatki

Automatically disconnects from grid during outages.

Zastrzezenie: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Pliki

Typ: DATASHEET_PDF

SE5000H-BUS Datasheet

Otwórz plik

Typ: INSTALLATION_MANUAL

SE5000H-BUS Installation Manual

Otwórz plik

Typ: CERTIFICATES

SE5000H-BUS Certificates

Otwórz plik

Typ: PRODUCT_IMAGE

SE5000H-BUS Product Image

Otwórz plik

Typ: PROMOTION_IMAGE

SE5000H-BUS Promotion Image

Otwórz plik

Typ: INSTALLATION_VIDEO

SE5000H-BUS Installation Video

Otwórz plik

Produkty powiązane