Energidea
Tesvolt PowerCore G2

Tesvolt

PowerCore G2

C&I Battery

Commercial and industrial battery rack/cabinet/container.

Energy (Nominal)

79.2

Energy (Usable)

79.2 kWh

Battery Chemistry

LFP

DC Voltage Range

705 - 907

Thermal Management

-

IP Rating

IP20

  • Uses high-quality Samsung SDI prismatic LFP cells for superior safety and density.
  • Proprietary active balancing system increases lifespan and performance.
  • Modular building block allows for multi-MWh scalability in container solutions.
C&IInstaller comparisonEU market

Applicable Countries

DE - GermanyAT - AustriaCH - SwitzerlandBE - BelgiumNL - NetherlandsLU - LuxembourgFR - FranceIT - ItalyES - SpainPL - Poland

Country notes: Targeted for the European C&I and Utility-scale market.

Installer AI Prompt

Generate installer-ready prompt templates for ChatGPT or Gemini.

Battery

Data source

Energy (Nominal)

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Energy (Usable)

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Battery Chemistry

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

DC Voltage Range

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

C-rate

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Max Charge Power

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Max Discharge Power

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Cycle Life

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

BMS Levels

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Energy (Nominal)79.2 kWh
Energy (Usable)79.2 kWh
Battery ChemistryLFP
DC Voltage Range705 - 907 V
C-rate1 C
Max Charge Power79 kW
Max Discharge Power79 kW
Cycle Life6000 cycles
BMS Levels3
Warranty Throughput / Cycles-

Environment & Mechanical

Data source

Thermal Management

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Thermal Management Detail

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Fire Suppression

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Detectors

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Pressure Relief

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Thermal Runaway Mitigation

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Lifting Method

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Maintenance Access

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Service Interval

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Noise

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

IP Rating

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Corrosion Rating

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

BMS Architecture

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Interfaces / Protocols

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Dimensions (W x H x D)

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Weight

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

Thermal Management-
Thermal Management DetailActive air circulation within the rack/cabinet.
Fire SuppressionAerosol (optional)
DetectorsVoltage, current, and temperature monitoring per cell.
Pressure Relieftrue
Thermal Runaway MitigationPrismatic LFP safety features and multi-tier BMS disconnection.
Balancing-
Lifting MethodForklift / Crane points
Maintenance AccessFront Access
Service IntervalAnnual check recommended.
Noise-
IP RatingIP20
Corrosion RatingC2
BMS ArchitectureCentralized Battery Control Unit with module-level monitoring.
Interfaces / ProtocolsCAN, RS485, Ethernet
Dimensions (W x H x D)600 x 2000 x 1000 mm
Weight750 kg

Compliance & Warranty

Data source

Certifications

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

System Certifications

Source URL: https://www.tesvolt.com/en/powercore.html

Source Version: 2024.1

CertificationsIEC 62619, CE, UN 38.3
System CertificationsVDE-AR-E 2510-50

Typical System Setup

Grid Support

Frequency regulation and grid stability services.

Grid Type: Medium Voltage Grid (via Transformer)

Suitable For: Utilities and large energy parks.

Main Components

Tesvolt PowerCore racks, Central PCS, Grid Transformer.

Disclaimer: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Industrial Energy Shifting

Peak shaving and self-consumption optimization for heavy industry.

Grid Type: 3-Phase TN/TT

Suitable For: Manufacturing plants and factories.

Main Components

PowerCore G2 racks, Tesvolt Energy Manager Pro, C&I Inverter.

Disclaimer: For reference only. Final system configuration should be confirmed based on local regulations, grid requirements, and project conditions.

Files

Type: DATASHEET_PDF

PowerCore G2 Datasheet

Open file

Type: BROCHURE

PowerCore G2 Brochure

Open file

Type: PRODUCT_IMAGE

PowerCore G2 Product Image

Open file