Resumen de la serie de productos
SolaX X3-IES
7 Submodelos

Selling Points
- UPS-level <10ms switchover time for seamless critical load protection.
- All-in-one modular stack design (5.1kWh modules) for fast 30-minute installation.
- Robust IP66 protection and built-in Type II SPD on both AC and DC sides.
Países aplicables
AustriaBelgiumSwitzerlandCzechiaGermanySpainFranceHungaryIrelandItalyLuxembourgNetherlandsPolandRomaniaUnited Kingdom
Submodelos
7
Prompt AI para instaladores
Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.
Technical Data
| Campo | SolaX X3-IES-10K Ver modelo | SolaX X3-IES-12K Ver modelo | SolaX X3-IES-15K Ver modelo | SolaX X3-IES-4K Ver modelo | SolaX X3-IES-5K Ver modelo | SolaX X3-IES-6K Ver modelo | SolaX X3-IES-8K Ver modelo |
|---|---|---|---|---|---|---|---|
| Core Electrical | |||||||
| AC Phase | 3P | 3P | 3P | 3P | 3P | 3P | 3P |
| AC Rated Power | 10 kW | 12 kW | 15 kW | 4 kW | 5 kW | 6 kW | 8 kW |
| Max AC Output Current | 16 A | 19.1 A | 24 A | 6.4 A | 8 A | 9.6 A | 12.8 A |
| Power Factor Range | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging | 0.8 leading ~ 0.8 lagging |
| THD | - | - | - | - | - | - | - |
| MPPT Count | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Max DC Voltage | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
| MPPT Voltage Range | 110-950 V | 110-950 V | 110-950 V | 110-950 V | 110-950 V | 110-950 V | 110-950 V |
| Max Current per MPPT | - | - | - | - | - | - | - |
| Recommended PV Power | 20 kWp | 24 kWp | 30 kWp | 8 kWp | 10 kWp | 12 kWp | 16 kWp |
| Max Efficiency | 98.3 % | 98.3 % | 98.3 % | 98.3 % | 98.3 % | 98.3 % | 98.3 % |
| EU Efficiency | 97.8 % | 97.8 % | 97.8 % | 97.8 % | 97.8 % | 97.8 % | 97.8 % |
| Battery | |||||||
| Battery Chemistry | LFP | LFP | LFP | LFP | LFP | LFP | LFP |
| Battery Voltage Class | HV | HV | HV | HV | HV | HV | HV |
| Battery Capacity Min | 9.2 kWh | 9.2 kWh | 9.2 kWh | 9.2 kWh | 9.2 kWh | 9.2 kWh | 9.2 kWh |
| Battery Capacity Max | 27.6 kWh | 27.6 kWh | 27.6 kWh | 27.6 kWh | 27.6 kWh | 27.6 kWh | 27.6 kWh |
| Max Charge Power | 10 kW | 12 kW | 15 kW | 4 kW | 5 kW | 6 kW | 8 kW |
| Max Discharge Power | 10 kW | 12 kW | 15 kW | 4 kW | 5 kW | 6 kW | 8 kW |
| Round-trip Efficiency | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % | 95 % |
| Backup | |||||||
| Backup / EPS Supported | true | true | true | true | true | true | true |
| Backup Rated Power | 10 kW | 12 kW | 15 kW | 4 kW | 5 kW | 6 kW | 8 kW |
| Switch Time | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms |
| Black Start | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Parallel Support | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Max Parallel Units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units |
| Generator Input Supported | true | true | true | true | true | true | true |
| EMS & Communication | |||||||
| EMS Modes | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual | Self-use, Feed-in Priority, Backup, Manual |
| Export Limitation Supported | true | true | true | true | true | true | true |
| Meter Type Supported | Three-phase meter, CT | Three-phase meter, CT | Three-phase meter, CT | Three-phase meter, CT | Three-phase meter, CT | Three-phase meter, CT | Three-phase meter, CT |
| Remote Monitoring Platform | SolaXCloud | SolaXCloud | SolaXCloud | SolaXCloud | SolaXCloud | SolaXCloud | SolaXCloud |
| API Supported | - | - | - | - | - | - | - |
| Environment & Mechanical | |||||||
| Cooling Method | Natural | Natural | Natural | Natural | Natural | Natural | Natural |
| IP Rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating Temp Range | -30 to 53 | -30 to 53 | -30 to 53 | -30 to 53 | -30 to 53 | -30 to 53 | -30 to 53 |
| Max Altitude | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m | 3000 m |
| Humidity Range | 0-100% (non-condensing) | 0-100% (non-condensing) | 0-100% (non-condensing) | 0-100% (non-condensing) | 0-100% (non-condensing) | 0-100% (non-condensing) | 0-100% (non-condensing) |
| Wiring Terminal Type | Plug & Play | Plug & Play | Plug & Play | Plug & Play | Plug & Play | Plug & Play | Plug & Play |
| Max Cable Size | - | - | - | - | - | - | - |
| Dimensions (W x H x D) | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm | 717 x 405 x 209.5 mm |
| Weight | 37 kg | 37 kg | 37 kg | 37 kg | 37 kg | 37 kg | 37 kg |
| Noise | 30 dB(A) | 30 dB(A) | 30 dB(A) | 30 dB(A) | 30 dB(A) | 30 dB(A) | 30 dB(A) |
| Compliance & Warranty | |||||||
| DC Surge Protection | Type II | Type II | Type II | Type II | Type II | Type II | Type II |
| AC Surge Protection | Type II | Type II | Type II | Type II | Type II | Type II | Type II |
| AFCI | - | - | - | - | - | - | - |
| Anti-islanding | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Certifications | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV | VDE4105, EN 50549, AS 4777, G98/G99, CE, TUV |