Panoramica della serie prodotti
Hoymiles HYS-LV-EUG1
5 Sotto-modelli

Selling Points
- Intelligent EMS supporting self-consumption, economic, and backup modes for multi-scenario applications.
- Excellent reliability and flexibility with support for up to 10 parallel inverters.
- UPS-level switching time (<10ms) ensures power security for critical loads.
Paesi applicabili
AustriaBelgiumGermanySpainFranceItalyNetherlandsPoland
Sotto-modelli
5
Prompt AI per installatori
Genera template di prompt pronti per installatori su ChatGPT o Gemini.
Technical Data
| Campo | Hoymiles HYS-3.0LV-EUG1 Vedi modello | Hoymiles HYS-3.6LV-EUG1 Vedi modello | Hoymiles HYS-4.6LV-EUG1 Vedi modello | Hoymiles HYS-5.0LV-EUG1 Vedi modello | Hoymiles HYS-6.0LV-EUG1 Vedi modello |
|---|---|---|---|---|---|
| Core Electrical | |||||
| AC Phase | 1P | 1P | 1P | 1P | 1P |
| AC Rated Power | 3 kW | 3.68 kW | 4.6 kW | 5 kW | 6 kW |
| Max AC Output Current | 13 A | 16 A | 20 A | 21.7 A | 26 A |
| Power Factor Range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| THD | 3 % | 3 % | 3 % | 3 % | 3 % |
| MPPT Count | 1 | 2 | 2 | 2 | 2 |
| Max DC Voltage | 550 V | 550 V | 550 V | 550 V | 550 V |
| MPPT Voltage Range | 125-500 V | 125-500 V | 125-500 V | 125-500 V | 125-500 V |
| Max Current per MPPT | 14 A | 14 A | 14 A | 14 A | 14 A |
| Max Efficiency | 97.6 % | 97.6 % | 97.6 % | 97.6 % | 97.6 % |
| EU Efficiency | 97 % | 97 % | 97 % | 97 % | 97 % |
| Battery | |||||
| Battery Voltage Class | LV | LV | LV | LV | LV |
| Battery DC Voltage Range | 40-60 V | 40-60 V | 40-60 V | 40-60 V | 40-60 V |
| Max Charge Power | 3 kW | 3.6 kW | 4.6 kW | 5 kW | 5 kW |
| Max Discharge Power | 3 kW | 3.6 kW | 4.6 kW | 5 kW | 5 kW |
| Backup | |||||
| Backup / EPS Supported | true | true | true | true | true |
| Backup Rated Power | 3 kW | 3.68 kW | 4.6 kW | 5 kW | 6 kW |
| Switch Time | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms |
| Black Start | Yes | Yes | Yes | Yes | Yes |
| Parallel Support | Yes | Yes | Yes | Yes | Yes |
| Max Parallel Units | 10 units | 10 units | 10 units | 10 units | 10 units |
| Generator Input Supported | true | true | true | true | true |
| EMS & Communication | |||||
| EMS Modes | Self-consumption, economic mode, backup mode | Self-consumption, economic mode, backup mode | Self-consumption, economic mode, backup mode | Self-consumption, economic mode, backup mode | Self-consumption, economic mode, backup mode |
| Export Limitation Supported | true | true | true | true | true |
| Meter Type Supported | Single-phase smart meter | Single-phase smart meter | Single-phase smart meter | Single-phase smart meter | Single-phase smart meter |
| Remote Monitoring Platform | S-Miles Cloud | S-Miles Cloud | S-Miles Cloud | S-Miles Cloud | S-Miles Cloud |
| Environment & Mechanical | |||||
| Cooling Method | Natural | Natural | Natural | Natural | Natural |
| Max Altitude | 2000 m | 2000 m | 2000 m | 2000 m | 2000 m |
| IP Rating | IP65 | IP65 | IP65 | IP65 | IP65 |
| Operating Temp Range | -25 to 65 | -25 to 65 | -25 to 65 | -25 to 65 | -25 to 65 |
| Dimensions (W x H x D) | 502 x 461 x 202 mm | 502 x 461 x 202 mm | 502 x 461 x 202 mm | 502 x 461 x 202 mm | 502 x 461 x 202 mm |
| Weight | 24 kg | 24 kg | 24 kg | 24 kg | 24 kg |
| Interfaces | RS485, CAN, optional Wi-Fi/Ethernet/4G | RS485, CAN, optional Wi-Fi/Ethernet/4G | RS485, CAN, optional Wi-Fi/Ethernet/4G | RS485, CAN, optional Wi-Fi/Ethernet/4G | RS485, CAN, optional Wi-Fi/Ethernet/4G |
| Compliance & Warranty | |||||
| DC Surge Protection | Type II | Type II | Type II | Type II | Type II |
| AC Surge Protection | Type III | Type III | Type III | Type III | Type III |
| AFCI | Yes | Yes | Yes | Yes | Yes |
| Anti-islanding | Yes | Yes | Yes | Yes | Yes |
| Certifications | EN 50549, VDE-AR-N 4105, AS/NZS 4777.2, IEC 62109-1/-2, EN 61000-6-1/-3 | EN 50549, VDE-AR-N 4105, AS/NZS 4777.2, IEC 62109-1/-2, EN 61000-6-1/-3 | EN 50549, VDE-AR-N 4105, AS/NZS 4777.2, IEC 62109-1/-2, EN 61000-6-1/-3 | EN 50549, VDE-AR-N 4105, AS/NZS 4777.2, IEC 62109-1/-2, EN 61000-6-1/-3 | EN 50549, VDE-AR-N 4105, AS/NZS 4777.2, IEC 62109-1/-2, EN 61000-6-1/-3 |