Energidea

Przegląd serii produktów

GoodWe GoodWe SDT G2 Series

9 Podmodele

GoodWe GoodWe SDT G2 Series

Selling Points

  • 110% AC output overloading
  • 150% DC input oversizing
  • High power density and compact design

Kraje zastosowania

AustriaSwitzerlandGermany

Podmodele

9

Prompt AI dla instalatorów

Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.

Technical Data

Pole

GoodWe GW10KT-DT

Zobacz model

GoodWe GW12KT-DT

Zobacz model

GoodWe GW17KT-DT

Zobacz model

GoodWe GW20KT-DT

Zobacz model

GoodWe GW25KT-DT

Zobacz model

GoodWe GW4K-DT

Zobacz model

GoodWe GW5K-DT

Zobacz model

GoodWe GW6K-DT

Zobacz model

GoodWe GW8K-DT

Zobacz model
Core Electrical
AC Rated Power10 kW12 kW17 kW20 kW25 kW4 kW5 kW6 kW8 kW
AC Voltage400400400400400400400400400
Startup Voltage160 V160 V180 V180 V180 V160 V160 V160 V160 V
Max AC Output Current16 A20.3 A28.8 A31.9 A40.8 A6.4 A8 A9.6 A12.8 A
MPPT Count222222222
Strings per MPPT---------
Total Strings234452222
DC Inputs Count---------
Max DC Voltage1000 V1000 V1100 V1100 V1100 V1000 V1000 V1000 V1000 V
MPPT Voltage Range180~850 V180~850 V200~950 V200~950 V200~950 V180~850 V180~850 V180~850 V180~850 V
Max Current per MPPT---------
Max Short-circuit Current---------
Max Efficiency98.3 %98.3 %98.4 %98.4 %98.4 %98.3 %98.3 %98.3 %98.3 %
EU Efficiency97.7 %97.7 %97.7 %97.7 %97.7 %97.5 %97.5 %97.5 %97.6 %
EMS & Communication
Grid Support FunctionsActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency controlActive/Reactive power control, Frequency control
Remote O&M FeaturesSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portalSmart O&M, Monitoring via SEMS portal
Night Consumption1 W1 W1 W1 W1 W1 W1 W1 W1 W
Compliance & Warranty
PID Recovery---------
IV Curve Scantruetruetruetruetruetruetruetruetrue
AFCI---------
CertificationsVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CEVDE-AR-N 4105, VDE0126-1-1, EN50549-1, CE
Environment & Mechanical
Cooling MethodFanFanFanFanFanNaturalNaturalNaturalFan
Noise45 dB(A)45 dB(A)55 dB(A)55 dB(A)55 dB(A)34 dB(A)34 dB(A)34 dB(A)45 dB(A)
Max Altitude4000 m4000 m4000 m4000 m4000 m4000 m4000 m4000 m4000 m
IP RatingIP65IP65IP65IP65IP65IP65IP65IP65IP65
Operating Temp Range-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60-30 ~ 60
InterfacesRS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)RS485, WiFi or LAN (Optional)

Pliki

Typ: INSTALLATION_MANUAL

GoodWe GW10KT-DT · GoodWe GW10KT-DT Installation Manual

Otwórz plik

Typ: DATASHEET_PDF

GoodWe GW10KT-DT · GoodWe GW10KT-DT Datasheet

Otwórz plik

Typ: PRODUCT_IMAGE

GoodWe GW10KT-DT · GoodWe GW10KT-DT Product Image

Otwórz plik

Typ: DATASHEET_PDF

GoodWe GW17KT-DT · GoodWe GW17KT-DT Datasheet

Otwórz plik