Przegląd serii produktów
SOFAR SOFAR HYD KTL-3PH Series
6 Podmodele
Selling Points
-
Kraje zastosowania
GermanySpainFranceItalyUnited Kingdom
Podmodele
6
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | HYD 10KTL-3PH Zobacz model | HYD 15KTL-3PH Zobacz model | HYD 20KTL-3PH Zobacz model | HYD 5KTL-3PH Zobacz model | HYD 6KTL-3PH Zobacz model | HYD 8KTL-3PH Zobacz model |
|---|---|---|---|---|---|---|
| Core Electrical | ||||||
| AC Phase | 3P | 3P | 3P | 3P | 3P | 3P |
| AC Rated Power | 10 kW | 15 kW | 20 kW | 5 kW | 6 kW | 8 kW |
| Max AC Output Current | 16.7 A | 25 A | 33.3 A | 8.3 A | 10 A | 13.3 A |
| Power Factor Range | 1 default (0.8 leading to 0.8 lagging) | 1 default (0.8 leading to 0.8 lagging) | 1 default (0.8 leading to 0.8 lagging) | 1 default (0.8 leading to 0.8 lagging) | 1 default (0.8 leading to 0.8 lagging) | 1 default (0.8 leading to 0.8 lagging) |
| THD | - | - | - | - | - | - |
| MPPT Count | 2 | 2 | 2 | 2 | 2 | 2 |
| Max DC Voltage | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
| MPPT Voltage Range | 180-960 V | 180-960 V | 180-960 V | 180-960 V | 180-960 V | 180-960 V |
| Max Current per MPPT | 12.5 A | 25 A | 25 A | 12.5 A | 12.5 A | 12.5 A |
| Max Efficiency | 98.2 % | 98.2 % | 98.2 % | 98.2 % | 98.2 % | 98.2 % |
| EU Efficiency | 97.7 % | 97.7 % | 97.7 % | 97.7 % | 97.7 % | 97.7 % |
| Battery | ||||||
| Battery Voltage Class | HV | HV | HV | HV | HV | HV |
| Battery DC Voltage Range | 180-800 V | 180-800 V | 180-800 V | 180-800 V | 180-800 V | 180-800 V |
| Max Charge Power | 10 kW | 15 kW | 20 kW | 5 kW | 6 kW | 8 kW |
| Max Discharge Power | 10 kW | 15 kW | 20 kW | 5 kW | 6 kW | 8 kW |
| Backup | ||||||
| Backup / EPS Supported | true | true | true | true | true | true |
| Backup Rated Power | 10 kW | 15 kW | 20 kW | 5 kW | 6 kW | 8 kW |
| Switch Time | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms |
| Black Start | Yes | Yes | Yes | Yes | Yes | Yes |
| Parallel Support | Yes | Yes | Yes | Yes | Yes | Yes |
| Max Parallel Units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units |
| Generator Input Supported | true | true | true | true | true | true |
| EMS & Communication | ||||||
| EMS Modes | Self-use, Time-of-use, Passive, Battery Priority | Self-use, Time-of-use, Passive, Battery Priority | Self-use, Time-of-use, Passive, Battery Priority | Self-use, Time-of-use, Passive, Battery Priority | Self-use, Time-of-use, Passive, Battery Priority | Self-use, Time-of-use, Passive, Battery Priority |
| Export Limitation Supported | true | true | true | true | true | true |
| Meter Type Supported | Smart Meter (3-phase) | Smart Meter (3-phase) | Smart Meter (3-phase) | Smart Meter (3-phase) | Smart Meter (3-phase) | Smart Meter (3-phase) |
| Remote Monitoring Platform | Solarman | Solarman | Solarman | Solarman | Solarman | Solarman |
| Environment & Mechanical | ||||||
| Cooling Method | Fan | Fan | Fan | Fan | Fan | Fan |
| Max Altitude | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m |
| IP Rating | IP65 | IP65 | IP65 | IP65 | IP65 | IP65 |
| Operating Temp Range | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 |
| Dimensions (W x H x D) | 571*515*264 mm | 571*515*264 mm | 571*515*264 mm | 571*515*264 mm | 571*515*264 mm | 571*515*264 mm |
| Weight | 37 kg | 37 kg | 37 kg | 37 kg | 37 kg | 37 kg |
| Interfaces | true | true | true | true | true | true |
| Compliance & Warranty | ||||||
| DC Surge Protection | Type II | Type II | Type II | Type II | Type II | Type II |
| AC Surge Protection | Type III | Type III | Type III | Type III | Type III | Type III |
| AFCI | Yes | Yes | Yes | Yes | Yes | Yes |
| Anti-islanding | Yes | Yes | Yes | Yes | Yes | Yes |
| Certifications | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109 |