Technical Data

Pole

Fronius Primo GEN24 3.0 Plus

Zobacz model

Fronius Primo GEN24 3.6 Plus

Zobacz model

Fronius Primo GEN24 4.0 Plus

Zobacz model

Fronius Primo GEN24 4.6 Plus

Zobacz model

Fronius Primo GEN24 5.0 Plus

Zobacz model

Fronius Primo GEN24 6.0 Plus

Zobacz model

Fronius Primo-GEN24-3.0-Plus

Zobacz model

Fronius Primo-GEN24-4.6-Plus

Zobacz model

Fronius Primo-GEN24-6.0-Plus

Zobacz model
Core Electrical
AC Phase3P1P1P1P1P1P1P1P1P
AC Rated Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Max AC Output Current19.4 A23.7 A25.8 A27.5 A27.5 A27.5 A13 A20 A26.1 A
Power Factor Range0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.8 - 1 ind./cap.0.7 - 1 ind./cap.0.7 - 1 ind./cap.0.7 - 1 ind./cap.
THD------3 %3 %3 %
MPPT Count222222222
Max DC Voltage600 V600 V600 V600 V600 V600 V600 V600 V600 V
MPPT Voltage Range65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V65 - 530 V
Max Current per MPPT22 A22 A22 A22 A22 A22 A---
Max Efficiency97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %97.6 %
EU Efficiency97.2 %97.2 %97.2 %97.2 %97.2 %97.2 %---
Battery
Battery Voltage ClassHVHVHVHVHVHVHVHVHV
Battery DC Voltage Range150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V150 - 455 V
Max Charge Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Max Discharge Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Backup
Backup / EPS Supportedtruetruetruetruetruetruetruetruetrue
Backup Rated Power3 kW3.68 kW4 kW4.6 kW5 kW6 kW3 kW4.6 kW6 kW
Switch Time90000 ms90000 ms90000 ms90000 ms90000 ms90000 ms---
Black StartYesYesYesYesYesYesYesYesYes
Parallel SupportYesYesYesYesYesYesYesYesYes
Max Parallel Units3 units3 units3 units3 units3 units3 units3 units3 units3 units
Generator Input Supported------falsefalsefalse
EMS & Communication
EMS ModesSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption, Multi-flow, PV PointSelf-consumption optimizationSelf-consumption optimizationSelf-consumption optimization
Export Limitation Supportedtruetruetruetruetruetruetruetruetrue
Meter Type Supported------Fronius Smart MeterFronius Smart MeterFronius Smart Meter
Remote Monitoring PlatformSolar.webSolar.webSolar.webSolar.webSolar.webSolar.webFronius Solar.webFronius Solar.webFronius Solar.web
Environment & Mechanical
Cooling MethodFanFanFanFanFanFanFanFanFan
Max Altitude4000 m4000 m4000 m4000 m4000 m4000 m3000 m3000 m3000 m
IP RatingIP66IP66IP66IP66IP66IP66IP66IP66IP66
Operating Temp Range-40 to +60-40 to +60-40 to +60-40 to +60-40 to +60-40 to +60-25 - 60-25 - 60-25 - 60
Dimensions (W x H x D)530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm530 * 474 * 165 mm528 x 474 x 164 mm528 x 474 x 164 mm528 x 474 x 164 mm
Weight15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg15.4 kg
Interfaces------Modbus RTU, Modbus TCP, WLAN, EthernetModbus RTU, Modbus TCP, WLAN, EthernetModbus RTU, Modbus TCP, WLAN, Ethernet
Compliance & Warranty
DC Surge ProtectionType 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2Type 1 + 2---
AC Surge ProtectionType 3Type 3Type 3Type 3Type 3Type 3---
AFCIYesYesYesYesYesYes---
Anti-islandingYesYesYesYesYesYesYesYesYes
CertificationsVDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, AS/NZS 4777.2VDE-AR-N 4105, G98, G99, CEVDE-AR-N 4105, G98, G99, CEVDE-AR-N 4105, G98, G99, CE

Pliki

Typ: BROCHURE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Brochure

Otwórz plik

Typ: INSTALLATION_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Installation Video

Otwórz plik

Typ: COMMISSIONING_GUIDE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Commissioning Guide

Otwórz plik

Typ: MARKETING_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Marketing Video

Otwórz plik

Typ: PROMOTION_IMAGE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Promotion Image

Otwórz plik

Typ: CORPORATE_VIDEO

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Corporate Video

Otwórz plik

Typ: CERTIFICATES

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Certificates

Otwórz plik

Typ: DATASHEET_PDF

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Datasheet

Otwórz plik

Typ: INSTALLATION_MANUAL

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Installation Manual

Otwórz plik

Typ: WIRING_DIAGRAM

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Wiring Diagram

Otwórz plik

Typ: PRODUCT_IMAGE

Fronius Primo GEN24 3.0 Plus · Fronius Fronius Primo GEN24 3.0 Plus - Product Image

Otwórz plik

Typ: DATASHEET_PDF

Fronius Primo-GEN24-3.0-Plus · Fronius Primo-GEN24-3.0-Plus Datasheet

Otwórz plik

Typ: PRODUCT_IMAGE

Fronius Primo-GEN24-3.0-Plus · Fronius Primo-GEN24-3.0-Plus Product Image

Otwórz plik