Przegląd serii produktów
Solplanet ASW H-T2/T3 Serie
8 Podmodele

Selling Points
- 10ms UPS-level switching for critical loads.
- IP66-rated enclosure for harsh outdoor environments.
- High MPPT input current (20A for T2) supports modern bifacial modules.
Kraje zastosowania
BelgiumGermanySpainFranceItalyNetherlandsPoland
Podmodele
8
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | Solplanet ASW05H-T2 Zobacz model | Solplanet ASW06H-T2 Zobacz model | Solplanet ASW08H-T2 Zobacz model | Solplanet ASW08H-T3 Zobacz model | Solplanet ASW10H-T2 Zobacz model | Solplanet ASW10H-T3 Zobacz model | Solplanet ASW12H-T2 Zobacz model | Solplanet ASW12H-T3 Zobacz model |
|---|---|---|---|---|---|---|---|---|
| Core Electrical | ||||||||
| AC Phase | 3P | 3P | 3P | 3P | 3P | 3P | 3P | 3P |
| AC Rated Power | 5 kW | 6 kW | 8 kW | 8 kW | 10 kW | 10 kW | 12 kW | 12 kW |
| Max AC Output Current | 7.3 A | 8.7 A | 11.6 A | 11.6 A | 14.5 A | 14.5 A | 17.4 A | 17.4 A |
| Power Factor Range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| THD | 3 % | 3 % | 3 % | 3 % | 3 % | 3 % | 3 % | 3 % |
| MPPT Count | 2 | 2 | 2 | 3 | 2 | 3 | 2 | 3 |
| Max DC Voltage | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V |
| MPPT Voltage Range | 150 - 950 V | 150 - 950 V | 150 - 950 V | 150 - 950 V | 150 - 950 V | 150 - 950 V | 150 - 950 V | 150 - 950 V |
| Max Current per MPPT | 20 A | 20 A | 20 A | 16 A | 20 A | 16 A | 20 A | 16 A |
| Max Efficiency | 98 % | 98 % | 98.4 % | 98.4 % | 98.4 % | 98.4 % | 98.4 % | 98.4 % |
| EU Efficiency | 97.2 % | 97.2 % | 97.9 % | 97.9 % | 97.9 % | 97.9 % | 97.9 % | 97.9 % |
| Battery | ||||||||
| Battery Voltage Class | HV | HV | HV | HV | HV | HV | HV | HV |
| Battery DC Voltage Range | 120 - 600 V | 120 - 600 V | 120 - 600 V | 120 - 600 V | 120 - 600 V | 120 - 600 V | 120 - 600 V | 120 - 600 V |
| Max Charge Power | 5 kW | 6 kW | 8 kW | 8 kW | 10 kW | 10 kW | 12 kW | 12 kW |
| Max Discharge Power | 5 kW | 6 kW | 8 kW | 8 kW | 10 kW | 10 kW | 12 kW | 12 kW |
| Backup | ||||||||
| Backup / EPS Supported | true | true | true | true | true | true | true | true |
| Backup Rated Power | 5 kW | 6 kW | 8 kW | 8 kW | 10 kW | 10 kW | 12 kW | 12 kW |
| Switch Time | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms | 10 ms |
| Black Start | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Parallel Support | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Max Parallel Units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units | 10 units |
| Generator Input Supported | true | true | true | true | true | true | true | true |
| EMS & Communication | ||||||||
| EMS Modes | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual | Self-consumption, ToU, Manual |
| Export Limitation Supported | true | true | true | true | true | true | true | true |
| Meter Type Supported | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter | Solplanet Smart Meter |
| Remote Monitoring Platform | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud | Solplanet App / Cloud |
| Environment & Mechanical | ||||||||
| Cooling Method | Natural | Natural | Natural | Natural | Natural | Natural | Natural | Natural |
| Max Altitude | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m |
| IP Rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating Temp Range | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 | -25 to 60 |
| Dimensions (W x H x D) | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm | 545 x 465 x 205 mm |
| Weight | 24.5 kg | 24.5 kg | 26 kg | 26 kg | 26 kg | 26 kg | 26 kg | 26 kg |
| Interfaces | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet | WiFi, Bluetooth, RS485, CAN, Ethernet |
| Compliance & Warranty | ||||||||
| DC Surge Protection | Type II | Type II | Type II | Type II | Type II | Type II | Type II | Type II |
| AC Surge Protection | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated | Integrated |
| AFCI | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Anti-islanding | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Certifications | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 | VDE-AR-N 4105, EN 50549-1, CE, IEC 62109, G98, G99, AS/NZS 4777 |