Selling Points
- Advanced liquid cooling ensures a temperature difference of <3°C across cells.
- Highly integrated design with a footprint of only 1.69 square meters.
- Pre-installed and factory-tested units significantly reduce onsite deployment time.
Países aplicables
AustriaBelgiumGermanySpainFranceItalyLuxembourgNetherlands
Submodelos
2
Prompt AI para instaladores
Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.
Technical Data
| Campo | ESC-R100-211-CE Ver modelo | ESD768-05P220 Ver modelo |
|---|---|---|
| Core Electrical | ||
| AC Rated Power | 100 kW | 100 kW |
| AC Voltage | 400 | 400 |
| Energy (Nominal) | 211.23 kWh | 220 kWh |
| Energy (Usable) | - | - |
| C-rate (continuous) | 0.5 C | 0.5 C |
| Peak Power | 110 kW | 110 kW |
| Battery Chemistry | LFP | LFP |
| DC Voltage Range | 672 - 840 V | 672 - 864 V |
| System Round-trip Efficiency | - | - |
| Noise | - | - |
| EMS & Communication | ||
| EMS Included | true | true |
| Protocols | Modbus TCP, Modbus RTU | Modbus TCP, Modbus RTU |
| EMS Functions | Peak shaving, Demand management, TOU optimization | Peak Shaving, Demand Management, Self-Consumption Optimization |
| Remote Maintenance | true | true |
| Fault Diagnosis | true | true |
| Grid Support Functions Detail | Voltage and frequency regulation, Reactive power compensation | Voltage and frequency regulation support |
| Data Logging Interval | - | - |
| Response Time | - | - |
| Environment & Mechanical | ||
| Thermal Management | Liquid | Air |
| Fire Suppression | Total flooding (Perfluorohexanone/Aerosol) | Total flooding gas suppression system |
| Detectors | Smoke, temperature, combustible gas | Smoke, heat, and combustible gas detectors |
| Maintenance Access | Front Access | Front Access |
| Pressure Relief | true | true |
| Thermal Runaway Mitigation | Integrated pack-level liquid cooling and safety venting | Multi-level BMS protection and directional venting |
| Lifting Points | Top lifting ears | Top lifting ears |
| Service Interval | Annual | Annual |
| IP Rating | IP55 | IP55 |
| Corrosion Rating | C4 | C3 |
| Operating Temp Range | -30 to 50 | -20 to 50 |
| Dimensions (W x H x D) | 1300 x 1300 x 2280 mm | 1100 x 1100 x 2380 mm |
| Weight | 2800 kg | 2500 kg |
| Compliance & Warranty | ||
| Certifications | IEC 62619, IEC 62477, IEC 61000 | IEC 62619, IEC 62477, IEC 61000 |
| Battery Certifications | UN 38.3 | UN 38.3 |
| System Certifications | CE | CE |
| LVRT/HVRT | true | true |