Przegląd serii produktów
FelicityESS C&I ESS Cabinet
3 Podmodele
Selling Points
- Seamless 20ms transition between on-grid and off-grid modes
- High-density liquid cooling ensures lifespan exceeding 8000 cycles
- Highly integrated cabinet with built-in fire protection and IP55 rating
Kraje zastosowania
Nie określono. Skontaktuj się z dostawcą w sprawie zastosowania rynkowego.
Podmodele
3
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | FelicityESS FLM500-125/261 Zobacz model | FelicityESS FLS-ES232LC-S Zobacz model | FelicityESS FLS-MES215AF-S Zobacz model |
|---|---|---|---|
| Core Electrical | |||
| AC Rated Power | 125 kW | 100 kW | 100 kW |
| AC Voltage | 400 | 400 | 400 |
| Energy (Nominal) | 261.2 kWh | 232.9 kWh | 215 kWh |
| Energy (Usable) | 248.14 kWh | 221.25 kWh | 193.5 kWh |
| C-rate (continuous) | 0.5 C | 0.5 C | 0.5 C |
| Peak Power | 125 kW | 100 kW | 100 kW |
| Battery Chemistry | LFP | LFP | LFP |
| DC Voltage Range | - | 650 ~ 949 V | - |
| System Round-trip Efficiency | 87 % | 87 % | 87 % |
| Noise | 75 dB(A) | 75 dB(A) | 75 dB(A) |
| EMS & Communication | |||
| EMS Included | true | true | true |
| Protocols | Modbus TCP, Modbus RTU, Ethernet, RS485 | Modbus TCP, Modbus RTU, LAN, Ethernet | Modbus TCP, Modbus RTU, Ethernet, RS485 |
| EMS Functions | Remote monitoring via Fsolar APP, scheduling | Self-diagnosis, fault location, auto on/off grid switching | Monitoring, peak shaving, backup |
| Remote Maintenance | true | true | true |
| Fault Diagnosis | true | true | true |
| Grid Support Functions Detail | Peak shaving, frequency regulation, off-grid backup | Peak and frequency regulation via price arbitrage | On-grid/Off-grid machine for industrial parks |
| Data Logging Interval | - | - | - |
| Response Time | 20 ms | - | - |
| Environment & Mechanical | |||
| Thermal Management | Liquid | Liquid | - |
| Fire Suppression | Perfluoroacetone, Aerosol | Perfluoroacetone (FK5112), Aerosol, Water | Perfluoroacetone, Aerosol, Water |
| Detectors | Smoke, temperature, immersion sensors | Three-level fire protection system | Smoke, temperature |
| Maintenance Access | Front | Front | Front |
| Pressure Relief | true | true | true |
| Thermal Runaway Mitigation | true | true | true |
| Lifting Points | true | true | true |
| Service Interval | - | - | - |
| IP Rating | IP55 | IP54 | IP54 |
| Corrosion Rating | C4 | C4 | C4 |
| Operating Temp Range | -20 ~ 50 | -20 ~ 50 | -20 ~ 50 |
| Dimensions (W x H x D) | - | 1600 x 1400 x 2200 mm | - |
| Weight | - | 3000 kg | - |
| Compliance & Warranty | |||
| Certifications | - | - | - |
| Battery Certifications | - | IP67 | - |
| System Certifications | - | - | - |
| LVRT/HVRT | - | - | - |
| Warranty Throughput / Cycles | - | - | - |