Sungrow Sungrow PowerStack Series
4 Podmodele

Selling Points
- Pre-assembled and pre-configured for rapid site installation.
- Advanced liquid cooling ensures cell temperature variance < 3°C, extending life.
- High energy density cabinet design reduces required installation footprint.
Kraje zastosowania
AustriaBelgiumCzechiaGermanySpainFranceHungaryItalyNetherlandsPolandUnited Kingdom
Podmodele
4
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | Sungrow ST225CS-2H Zobacz model | Sungrow ST255CS-2H Zobacz model | Sungrow ST455CS-4H Zobacz model | Sungrow ST510CS-4H Zobacz model |
|---|---|---|---|---|
| Core Electrical | ||||
| AC Rated Power | 110 kW | 125 kW | 110 kW | 125 kW |
| AC Voltage | 400 | 400 | 400 | 400 |
| Energy (Nominal) | 240 kWh | 270 kWh | 480 kWh | 540 kWh |
| Energy (Usable) | 229 kWh | 257 kWh | 458 kWh | 514 kWh |
| C-rate (continuous) | - | - | - | - |
| Peak Power | 121.00000000000001 kW | 137.5 kW | 121.00000000000001 kW | 137.5 kW |
| Battery Chemistry | LFP | LFP | LFP | LFP |
| DC Voltage Range | 700-1100 V | 700-1100 V | 700-1100 V | 700-1100 V |
| System Round-trip Efficiency | 90 % | 90 % | 90 % | 90 % |
| Noise | 75 dB(A) | 75 dB(A) | 75 dB(A) | 75 dB(A) |
| EMS & Communication | ||||
| EMS Included | true | true | true | true |
| Protocols | Modbus TCP, Modbus RTU, IEC 61850 | Modbus TCP, Modbus RTU, IEC 61850 | Modbus TCP, Modbus RTU, IEC 61850 | Modbus TCP, Modbus RTU, IEC 61850 |
| EMS Functions | Peak Shaving, Demand Charge Management, Self-consumption, Backup | Peak Shaving, Demand Charge Management, Self-consumption, Backup | Peak Shaving, Demand Charge Management, Self-consumption, Backup | Peak Shaving, Demand Charge Management, Self-consumption, Backup |
| Remote Maintenance | true | true | true | true |
| Fault Diagnosis | - | - | - | - |
| Grid Support Functions Detail | Freq/Volt control, LVRT, HVRT, Active/Reactive power control | Freq/Volt control, LVRT, HVRT, Active/Reactive power control | Freq/Volt control, LVRT, HVRT, Active/Reactive power control | Freq/Volt control, LVRT, HVRT, Active/Reactive power control |
| Data Logging Interval | 1 s | 1 s | 1 s | 1 s |
| Response Time | - | - | - | - |
| Environment & Mechanical | ||||
| Thermal Management | Liquid | Liquid | Liquid | Liquid |
| Fire Suppression | NFPA 68 / NFPA 69 / NFPA 855 compliant, Aerosol or gas based | NFPA 68 / NFPA 69 / NFPA 855 compliant, Aerosol or gas based | NFPA 68 / NFPA 69 / NFPA 855 compliant, Aerosol or gas based | NFPA 68 / NFPA 69 / NFPA 855 compliant, Aerosol or gas based |
| Detectors | Smoke, heat, and gas detectors | Smoke, heat, and gas detectors | Smoke, heat, and gas detectors | Smoke, heat, and gas detectors |
| Maintenance Access | Front access | Front access | Front access | Front access |
| Pressure Relief | - | - | - | - |
| Thermal Runaway Mitigation | Cell-to-cell thermal insulation and active cooling | Cell-to-cell thermal insulation and active cooling | Cell-to-cell thermal insulation and active cooling | Cell-to-cell thermal insulation and active cooling |
| Lifting Points | Bottom forklift / Top lifting | Bottom forklift / Top lifting | Bottom forklift / Top lifting | Bottom forklift / Top lifting |
| Service Interval | Annual inspection | Annual inspection | Annual inspection | Annual inspection |
| IP Rating | IP55 | IP55 | IP55 | IP55 |
| Corrosion Rating | C4/C5 | C4/C5 | C4/C5 | C4/C5 |
| Operating Temp Range | -30 to 50 | -30 to 50 | -30 to 50 | -30 to 50 |
| Dimensions (W x H x D) | 1400*1500*2400 mm | 1400*1500*2400 mm | 2300*1500*2400 mm | 2300*1500*2400 mm |
| Weight | 2800 kg | 3000 kg | 4200 kg | 4500 kg |
| Compliance & Warranty | ||||
| Certifications | IEC 62619, IEC 62477, UN 38.3, CE | IEC 62619, IEC 62477, UN 38.3, CE | IEC 62619, IEC 62477, UN 38.3, CE | IEC 62619, IEC 62477, UN 38.3, CE |
| Battery Certifications | IEC 62619 | IEC 62619 | IEC 62619 | IEC 62619 |
| System Certifications | IEC 62477-1 | IEC 62477-1 | IEC 62477-1 | IEC 62477-1 |
| LVRT/HVRT | - | - | - | - |
| Warranty Throughput / Cycles | Project dependent | Project dependent | Project dependent | Project dependent |