Resumen de la serie de productos
SolaX X3-PRO G2
8 Submodelos

Selling Points
- High power density with up to 150% DC oversizing and 110% AC overloading.
- Excellent protection with IP66 rating and Type II SPD on both AC and DC sides.
- Smart management with built-in export control and heat pump/EV charger integration.
Países aplicables
AustriaBelgiumSwitzerlandCzechiaGermanySpainFranceHungaryIrelandItalyLuxembourgNetherlandsPolandRomaniaUnited Kingdom
Submodelos
8
Prompt AI para instaladores
Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.
Technical Data
| Campo | SolaX X3-PRO-10K-G2 Ver modelo | SolaX X3-PRO-12K-G2 Ver modelo | SolaX X3-PRO-15K-G2 Ver modelo | SolaX X3-PRO-17K-G2 Ver modelo | SolaX X3-PRO-20K-G2 Ver modelo | SolaX X3-PRO-25K-G2 Ver modelo | SolaX X3-PRO-30K-G2 Ver modelo | SolaX X3-PRO-8K-G2 Ver modelo |
|---|---|---|---|---|---|---|---|---|
| Core Electrical | ||||||||
| AC Rated Power | 10 kW | 12 kW | 15 kW | 17 kW | 20 kW | 25 kW | 30 kW | 8 kW |
| AC Voltage | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 | 230/400 |
| Startup Voltage | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V |
| Max AC Output Current | 15.2 A | 18.2 A | 22.8 A | 25.8 A | 30.3 A | 37.9 A | 45.5 A | 12.2 A |
| MPPT Count | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 2 |
| Strings per MPPT | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Total Strings | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 4 |
| DC Inputs Count | 4 | 4 | 4 | 4 | 4 | 6 | 6 | 4 |
| Max DC Voltage | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V |
| MPPT Voltage Range | 160-980 V | 160-980 V | 160-980 V | 160-980 V | 160-980 V | 160-980 V | 160-980 V | 160-980 V |
| Max Current per MPPT | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A |
| Max Short-circuit Current | 40 A | 40 A | 40 A | 40 A | 40 A | 40 A | 40 A | 40 A |
| Max Efficiency | 98.2 % | 98.2 % | 98.3 % | 98.3 % | 98.3 % | 98.5 % | 98.5 % | 98.2 % |
| EU Efficiency | 97.7 % | 97.7 % | 97.8 % | 97.8 % | 97.8 % | 98 % | 98 % | 97.7 % |
| EMS & Communication | ||||||||
| Grid Support Functions | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) | Built-in export power control, smart loads management (heat pump, EV charger) |
| Remote O&M Features | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan | 24h monitoring (WiFi/LAN/4G), built-in global MPP scan |
| Night Consumption | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W | 3 W |
| Compliance & Warranty | ||||||||
| PID Recovery | - | - | - | - | - | - | - | - |
| IV Curve Scan | - | - | - | - | - | - | - | - |
| AFCI | - | - | - | - | - | - | - | - |
| Certifications | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 | VDE4105, EN 50549, AS 4777.2, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530, NB/T 32004, IEC/EN 62109-1, IEC/EN 62109-2 |
| Environment & Mechanical | ||||||||
| Cooling Method | Natural | Natural | Natural | Natural | Natural | Fan | Fan | Natural |
| Noise | - | - | - | - | - | - | - | - |
| Max Altitude | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m |
| IP Rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating Temp Range | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 |
| Interfaces | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) | RS485/DRM, USB, WiFi/LAN/4G (optional) |