Przegląd serii produktów
SolaX X3-MEGA G2
3 Podmodele

Selling Points
- High power density with optimized heat dissipation reducing weight/size by 10% compared to previous generations.
- Intelligent string monitoring and IV curve diagnosis for efficient O&M.
- Robust IP66 protection with optional AFCI and SPDs on both AC and DC sides.
Kraje zastosowania
GermanySpainItalyNetherlandsUnited Kingdom
Podmodele
3
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | SolaX X3-MGA-40K-G2 Zobacz model | SolaX X3-MGA-50K-G2 Zobacz model | SolaX X3-MGA-60K-G2 Zobacz model |
|---|---|---|---|
| Core Electrical | |||
| AC Rated Power | 40 kW | 50 kW | 60 kW |
| AC Voltage | 230 / 400 | 230 / 400 | 230 / 400 |
| Startup Voltage | 200 V | 200 V | 200 V |
| Max AC Output Current | 63.8 A | 79.7 A | 95.7 A |
| MPPT Count | 4 | 5 | 6 |
| Strings per MPPT | 2 | 2 | 2 |
| Total Strings | 8 | 10 | 12 |
| DC Inputs Count | 8 | 10 | 12 |
| Max DC Voltage | 1100 V | 1100 V | 1100 V |
| MPPT Voltage Range | 180-1000 V | 180-1000 V | 180-1000 V |
| Max Current per MPPT | 32 A | 32 A | 32 A |
| Max Short-circuit Current | 46 A | 46 A | 46 A |
| Max Efficiency | 98.4 % | 98.4 % | 98.4 % |
| EU Efficiency | 98.1 % | 98.1 % | 98.1 % |
| EMS & Communication | |||
| Grid Support Functions | Built-in export power control, Night-time reactive power compensation | Built-in export power control, Night-time reactive power compensation | Built-in export power control, Night-time reactive power compensation |
| Remote O&M Features | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring |
| Night Consumption | 2 W | 2 W | 2 W |
| Compliance & Warranty | |||
| PID Recovery | true | true | true |
| IV Curve Scan | true | true | true |
| AFCI | Yes | Yes | Yes |
| Certifications | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 |
| Environment & Mechanical | |||
| Cooling Method | Fan | Fan | Fan |
| Noise | - | - | - |
| Max Altitude | 4000 m | 4000 m | 4000 m |
| IP Rating | IP66 | IP66 | IP66 |
| Operating Temp Range | -25 to 60 | -25 to 60 | -25 to 60 |
| Interfaces | RS485, DRM, Meter | RS485, DRM, Meter | RS485, DRM, Meter |