Resumen de la serie de productos
SolaX X3-FORTH
8 Submodelos

Selling Points
- High energy density and efficiency up to 99% for commercial solar systems.
- Smart I-V curve diagnosis reduces O&M time and increases system uptime.
- Robust IP66 protection with smart fan cooling for reliable outdoor performance.
Países aplicables
GermanySpainItalyNetherlandsUnited Kingdom
Submodelos
8
Prompt AI para instaladores
Genera plantillas de prompt listas para instaladores en ChatGPT o Gemini.
Technical Data
| Campo | SolaX X3-FTH-100K Ver modelo | SolaX X3-FTH-110K Ver modelo | SolaX X3-FTH-120K Ver modelo | SolaX X3-FTH-125K Ver modelo | SolaX X3-FTH-136K-MV Ver modelo | SolaX X3-FTH-150K-MV Ver modelo | SolaX X3-FTH-75K Ver modelo | SolaX X3-FTH-80K Ver modelo |
|---|---|---|---|---|---|---|---|---|
| Core Electrical | ||||||||
| AC Rated Power | 100 kW | 110 kW | 120 kW | 125 kW | 136 kW | 150 kW | 75 kW | 80 kW |
| AC Voltage | 220 / 380, 230 / 400 | 220 / 380, 230 / 400 | 220 / 380, 230 / 400 | 220 / 380, 230 / 400 | 500 / 540 | 500 / 540 | 220 / 380, 230 / 400 | 220 / 380, 230 / 400 |
| Startup Voltage | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V | 200 V |
| Max AC Output Current | 151.6 A | 166.7 A | 181.9 A | 189.4 A | 157.1 A | 173.2 A | 113.7 A | 121.3 A |
| MPPT Count | 9 | 9 | 12 | 12 | 12 | 12 | 9 | 9 |
| Strings per MPPT | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| Total Strings | 18 | 18 | 24 | 24 | 24 | 24 | 18 | 18 |
| DC Inputs Count | 18 | 18 | 24 | 24 | 24 | 24 | 18 | 18 |
| Max DC Voltage | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V | 1100 V |
| MPPT Voltage Range | 180-1000 V | 180-1000 V | 180-1000 V | 180-1000 V | 180-1000 V | 180-1000 V | 180-1000 V | 180-1000 V |
| Max Current per MPPT | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A | 32 A |
| Max Short-circuit Current | 46 A | 46 A | 46 A | 46 A | 46 A | 46 A | 46 A | 46 A |
| Max Efficiency | 98.6 % | 98.6 % | 98.6 % | 98.6 % | 99 % | 99 % | 98.6 % | 98.6 % |
| EU Efficiency | 98.3 % | 98.3 % | 98.3 % | 98.3 % | 98.5 % | 98.5 % | 98.3 % | 98.3 % |
| EMS & Communication | ||||||||
| Grid Support Functions | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation | Export power control, Night-time reactive power compensation |
| Remote O&M Features | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring | Remote setting and upgrading, Smart string current monitoring |
| Night Consumption | 10 W | 10 W | 10 W | 10 W | 10 W | 10 W | 10 W | 10 W |
| Compliance & Warranty | ||||||||
| PID Recovery | true | true | true | true | true | true | true | true |
| IV Curve Scan | true | true | true | true | true | true | true | true |
| AFCI | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Certifications | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 | IEC/EN 62109-1, IEC/EN 62109-2, EN 50549, AS4777.2, VDE4105, IEC 61727, IEC 62116, IEC 61683, IEC 60068, EN 50530 |
| Environment & Mechanical | ||||||||
| Cooling Method | Fan | Fan | Fan | Fan | Fan | Fan | Fan | Fan |
| Noise | - | - | - | - | - | - | - | - |
| Max Altitude | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m | 4000 m |
| IP Rating | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 | IP66 |
| Operating Temp Range | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 | -30 to 60 |
| Interfaces | RS485, DRM | RS485, DRM | RS485, DRM | RS485, DRM | RS485, DRM | RS485, DRM | RS485, DRM | RS485, DRM |