Panoramica della serie prodotti
SENEC SENEC.P4 Series
4 Sotto-modelli

Selling Points
-
Paesi applicabili
AustriaSwitzerlandGermany
Sotto-modelli
4
Prompt AI per installatori
Genera template di prompt pronti per installatori su ChatGPT o Gemini.
Technical Data
| Campo | P4 10.0 Vedi modello | P4 4.6 Vedi modello | P4 6.0 Vedi modello | P4 8.0 Vedi modello |
|---|---|---|---|---|
| Core Electrical | ||||
| AC Phase | 3P | 3P | 3P | 3P |
| AC Rated Power | 10 kW | 4.6 kW | 6 kW | 8 kW |
| Max AC Output Current | - | - | - | - |
| Power Factor Range | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging | 0.8 leading - 0.8 lagging |
| THD | - | - | - | - |
| MPPT Count | 2 | 2 | 2 | 2 |
| Max DC Voltage | 1000 V | 1000 V | 1000 V | 1000 V |
| MPPT Voltage Range | 160-800 V | 160-800 V | 160-800 V | 160-800 V |
| Max Current per MPPT | 16 A | 16 A | 16 A | 16 A |
| Recommended PV Power | 15 kWp | 7 kWp | 9 kWp | 12 kWp |
| Max Efficiency | 97.6 % | 97.6 % | 97.6 % | 97.6 % |
| EU Efficiency | 97 % | 97 % | 97 % | 97 % |
| Battery | ||||
| Battery Chemistry | LFP | LFP | LFP | LFP |
| Battery Voltage Class | HV | HV | HV | HV |
| Battery Capacity Min | 4.2 kWh | 4.2 kWh | 4.2 kWh | 4.2 kWh |
| Battery Capacity Max | 21 kWh | 21 kWh | 21 kWh | 21 kWh |
| Max Charge Power | 10 kW | 4.6 kW | 6 kW | 8 kW |
| Max Discharge Power | 10 kW | 4.6 kW | 6 kW | 8 kW |
| Round-trip Efficiency | - | - | - | - |
| Backup | ||||
| Backup / EPS Supported | true | true | true | true |
| Backup Rated Power | 10 kW | 4.6 kW | 6 kW | 8 kW |
| Switch Time | 15000 ms | 15000 ms | 15000 ms | 15000 ms |
| Black Start | Yes | Yes | Yes | Yes |
| Parallel Support | No | No | No | No |
| Max Parallel Units | - | - | - | - |
| Generator Input Supported | - | - | - | - |
| EMS & Communication | ||||
| EMS Modes | Self-consumption, Backup, TOU | Self-consumption, Backup, TOU | Self-consumption, Backup, TOU | Self-consumption, Backup, TOU |
| Export Limitation Supported | true | true | true | true |
| Meter Type Supported | SENEC.SmartMeter P4 | SENEC.SmartMeter P4 | SENEC.SmartMeter P4 | SENEC.SmartMeter P4 |
| Remote Monitoring Platform | SENEC.App / meine-energie.de | SENEC.App / meine-energie.de | SENEC.App / meine-energie.de | SENEC.App / meine-energie.de |
| API Supported | true | true | true | true |
| Environment & Mechanical | ||||
| Cooling Method | - | - | - | - |
| IP Rating | IP20 | IP20 | IP20 | IP20 |
| Operating Temp Range | 5-40 | 5-40 | 5-40 | 5-40 |
| Max Altitude | 2000 m | 2000 m | 2000 m | 2000 m |
| Humidity Range | 10-85% | 10-85% | 10-85% | 10-85% |
| Wiring Terminal Type | - | - | - | - |
| Max Cable Size | - | - | - | - |
| Dimensions (W x H x D) | - | - | - | - |
| Weight | - | - | - | - |
| Noise | - | - | - | - |
| Compliance & Warranty | ||||
| DC Surge Protection | Type II | Type II | Type II | Type II |
| AC Surge Protection | Type II | Type II | Type II | Type II |
| AFCI | Yes | Yes | Yes | Yes |
| Anti-islanding | Yes | Yes | Yes | Yes |
| Certifications | VDE-AR-N 4105, UN 38.3, CE | VDE-AR-N 4105, UN 38.3, CE | VDE-AR-N 4105, UN 38.3, CE | VDE-AR-N 4105, UN 38.3, CE |