Przegląd serii produktów
Dyness Tower S3
5 Podmodele

Selling Points
- Modular stackable design for easy installation and expansion.
- High-voltage architecture for superior efficiency.
- Broad compatibility with leading hybrid inverter brands.
Kraje zastosowania
AustriaBelgiumBulgariaCyprusCzechiaGermanyDenmarkEstoniaSpainFinlandFranceGreeceCroatiaHungaryIrelandItalyLithuaniaLuxembourgLatviaMaltaNetherlandsPolandPortugalRomaniaSwedenSloveniaSlovakia
Podmodele
5
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | Dyness Tower TS10 Zobacz model | Dyness Tower TS14 Zobacz model | Dyness Tower TS17 Zobacz model | Dyness Tower TS21 Zobacz model | Dyness Tower TS7 Zobacz model |
|---|---|---|---|---|---|
| Battery | |||||
| Battery Chemistry | LFP | LFP | LFP | LFP | LFP |
| Battery Voltage Class | HV | HV | HV | HV | HV |
| Capacity (Nominal) | 10.66 kWh | 14.21 kWh | 17.76 kWh | 21.31 kWh | 7.1 kWh |
| Capacity (Usable) | 10.127 kWh | 13.499 kWh | 16.872 kWh | 20.245 kWh | 6.745 kWh |
| Nominal Voltage | 288 V | 384 V | 480 V | 576 V | 192 V |
| Voltage Range | 252 ~ 328 V | 336 ~ 437 V | 420 ~ 547 V | 504 ~ 656 V | 168 ~ 218 V |
| Min Modules | 2 | 2 | 2 | 2 | 2 |
| Max Modules | 6 | 6 | 6 | 6 | 6 |
| Installation Type | - | - | - | - | - |
| Capacity Scalability Min | 7.1 kWh | 7.1 kWh | 7.1 kWh | 7.1 kWh | 7.1 kWh |
| Capacity Scalability Max | 255.72 kWh | 255.72 kWh | 255.72 kWh | 255.72 kWh | 255.72 kWh |
| Max Charge Power | 6.39 kW | 8.52 kW | 10.65 kW | 12.78 kW | 4.26 kW |
| Max Discharge Power | 6.39 kW | 8.52 kW | 10.65 kW | 12.78 kW | 4.26 kW |
| Peak Discharge Power | - | - | - | - | - |
| Cycle Life | 6000 cycles | 6000 cycles | 6000 cycles | 6000 cycles | 6000 cycles |
| DoD | 95 % | 95 % | 95 % | 95 % | 95 % |
| Round-trip Efficiency | 95 % | 95 % | 95 % | 95 % | 95 % |
| Environment & Mechanical | |||||
| IP Rating | IP54 | IP54 | IP54 | IP54 | IP54 |
| Charge Temp Range | 0 ~ 50 | 0 ~ 50 | 0 ~ 50 | 0 ~ 50 | 0 ~ 50 |
| Discharge Temp Range | -10 ~ 50 | -10 ~ 50 | -10 ~ 50 | -10 ~ 50 | -10 ~ 50 |
| Heating Supported | false | false | false | false | false |
| Dimensions (W x H x D) | 504*380*920 mm | 504*380*1120 mm | 504*380*1320 mm | 504*380*1520 mm | 504*380*720 mm |
| Weight | 143 kg | 183 kg | 223 kg | 263 kg | 103 kg |
| EMS & Communication | |||||
| BMS Interfaces | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 | CAN / RS485 |
| Compatible Inverters | Kostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt | Kostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt | Kostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt | Kostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt | Kostal, Goodwe, Solis, Deye, Solplanet, Solinteg, Sunways, SAJ, Sinexcel, Hoymiles, Growatt |
| BMS Update Supported | true | true | true | true | true |
| Compliance & Warranty | |||||
| Certifications | UN38.3, CE-EMC, IEC62619, IEC62040, UKCA | UN38.3, CE-EMC, IEC62619, IEC62040, UKCA | UN38.3, CE-EMC, IEC62619, IEC62040, UKCA | UN38.3, CE-EMC, IEC62619, IEC62040, UKCA | UN38.3, CE-EMC, IEC62619, IEC62040, UKCA |
| Shipping Certifications | UN38.3 | UN38.3 | UN38.3 | UN38.3 | UN38.3 |