Przegląd serii produktów
Dyness DH100F
3 Podmodele

Selling Points
- All-in-one integration reduces infrastructure costs and simplifies installation.
- Highly safe with three-level fire detection and preventive explosion-proof technology.
- Flexible expansion supporting standalone or parallel operation up to 8 cabinets.
Kraje zastosowania
AustriaBelgiumBulgariaCyprusCzechiaGermanyDenmarkEstoniaSpainFinlandFranceGreeceCroatiaHungaryIrelandItalyLithuaniaLuxembourgLatviaMaltaNetherlandsPolandPortugalRomaniaSwedenSloveniaSlovakia
Podmodele
3
Prompt AI dla instalatorów
Generuj gotowe dla instalatorów szablony promptów do ChatGPT lub Gemini.
Technical Data
| Pole | Dyness DH100F-100 Zobacz model | Dyness DH100F-71 Zobacz model | Dyness DH100F-86 Zobacz model |
|---|---|---|---|
| Core Electrical | |||
| AC Rated Power | 50 kW | 35 kW | 40 kW |
| AC Voltage | 400 | 400 | 400 |
| Energy (Nominal) | 100 kWh | 71 kWh | 86 kWh |
| Energy (Usable) | 100 kWh | 71 kWh | 86 kWh |
| C-rate (continuous) | - | - | - |
| Peak Power | 55.00000000000001 kW | 38.5 kW | 44 kW |
| Battery Chemistry | LFP | LFP | LFP |
| DC Voltage Range | 300 ~ 1000 V | 300 ~ 1000 V | 300 ~ 1000 V |
| System Round-trip Efficiency | 90 % | 90 % | 90 % |
| Noise | - | - | - |
| EMS & Communication | |||
| EMS Included | true | true | true |
| Protocols | Ethernet, RS485, CAN, USB | Ethernet, RS485, CAN, USB | Ethernet, RS485, CAN, USB |
| EMS Functions | Peak shaving, load management, timed scheduling, PV self-generation | Peak shaving, load management, timed scheduling, PV self-generation | Peak shaving, load management, timed scheduling, PV self-generation |
| Remote Maintenance | true | true | true |
| Fault Diagnosis | true | true | true |
| Grid Support Functions Detail | On-grid/Off-grid switching, supports generator access | On-grid/Off-grid switching, supports generator access | On-grid/Off-grid switching, supports generator access |
| Data Logging Interval | - | - | - |
| Response Time | - | - | - |
| Environment & Mechanical | |||
| Thermal Management | - | - | - |
| Fire Suppression | Aerosol | Aerosol | Aerosol |
| Detectors | Heat, Smoke | Heat, Smoke | Heat, Smoke |
| Maintenance Access | Front | Front | Front |
| Pressure Relief | true | true | true |
| Thermal Runaway Mitigation | Three-level detection, active/passive explosion-proof | Three-level detection, active/passive explosion-proof | Three-level detection, active/passive explosion-proof |
| Lifting Points | true | true | true |
| Service Interval | - | - | - |
| IP Rating | IP55 | IP55 | IP55 |
| Corrosion Rating | C3 | C3 | C3 |
| Operating Temp Range | -20 ~ 50 | -20 ~ 50 | -20 ~ 50 |
| Dimensions (W x H x D) | 1200*1048*2258 mm | 1200*1048*2258 mm | 1200*1048*2258 mm |
| Weight | 1650 kg | 1650 kg | 1650 kg |
| Compliance & Warranty | |||
| Certifications | CE, IEC 62619, VDE 2510-50, UL1973, UL9540A, UN38.3 | CE, IEC 62619, VDE 2510-50, UL1973, UL9540A, UN38.3 | CE, IEC 62619, VDE 2510-50, UL1973, UL9540A, UN38.3 |
| Battery Certifications | IEC 62619, UL 1973 | IEC 62619, UL 1973 | IEC 62619, UL 1973 |
| System Certifications | CE, VDE 2510-50 | CE, VDE 2510-50 | CE, VDE 2510-50 |
| LVRT/HVRT | true | true | true |
| Warranty Throughput / Cycles | - | - | - |